10.2 LK1900B
1
.
Startup of XY Motor/Origin Sensor Check Mode "02 X/Y Motor Origin Adjustment"
2
.
Origin Sensor Slit Adjustment
・
Press the returning key
❾
to return to the
Check Program screen.
※
After the adjustment, tighten the screws
❶
and
install the bed carver.
・
Press the Item Selection Key
❻
on the Check
Program screen, select 02 X/Y Motor Origin
Adjustment, and then press Edit Key
❽
to use the
selected function.
・
When the Preparation LED
⓮
is turned off
and the Mode key
❹
is pressed for 3 seconds, the
beeper will beep and the "13 Check Program" will
appear on the Mode screen.
・
Press the Item Selection Key
❻
to drive
the X motor by ±0.1 mm.
A This box indicates the X-ray motor encoder
position information.
Pressing the data change key
❼
drives Y motor
by ±0.1 mm in increments.
B This box indicates the Y motor encoder
position information.
・
Adjust the button gauge so that the center
hole and needle tip are aligned by changing the
selection key
❻
and change key
❼
.
・
When the center hole of the button gauge is
aligned with the tip of the needle, press the
preparation key
❷
for 2 seconds to bring the
current position to the XY origin.
❶
●
A typical button can
be used instead of a
button gauge.
At that time, adjust the
tip of the needle to the
center of the button.
Center of the Button
Needle
Needle
Center hole of the
button gauge
11Page