3. Remove desired “knock out” to route utility power input and camera power output leads
into the enclosure. Mount the PS1 in the desired location using the four screw holes on the
mounting bracket.
4.
Power Leads
The blue wire leads on the transformer are to be connected to 120 volt, utility power. One
blue lead is connected to the fuse holder. Connect the fuse holder lead and one blue lead to
main utility hot and neutral leads. Connect the utility ground (green) lead to the ground lug
on the chassis. Connect the red, 24 volt output, leads to the camera.
5. Replace front panel and secure with the 4 screws provided.
6.
Fuse Replacement
– Always turn off power to the PS1 before replacing the fuse. Use a
maximum 1 amp fuse in the PS1-24.
TROUBLE SHOOTING
Before trouble shooting this power supply disconnect the power. If there is no power output check the
fuse and power connections, both input and output.
REPAIR
Should your PS1 need service contact Juice Goose for assistance and authorization to return the unit.
PLEASE NOTE: a return authorization number is required in order for the service personnel to correctly
and promptly identify, repair and return your unit.
You may obtain a Return Authorization Number by calling: 713-772-1404 or sending email to
[email protected].
DIMENSIONS (INCHES)
6.0 x 6.0 x 4.0
WEIGHT (LBS)
7
POWER INPUT
120 VAC, 60Hz
POWER OUTLETS
RED WIRE LEADS
CURRENT CAPACITY
.75 Amps @ 120 VAC
3.75 AMPS @ 24 VAC
CURRENT OVERLOAD PROTECTION
1 AMP MASTER CIRCUIT
CHASSIS DESIGN
NEMA 1 METAL ENCLOSURE
CHASSIS FINISH
POWDER COAT ENAMEL – TAN
SPECIFICATIONS
PS1-24 Owners Manual.pub
page 3