background image

3. Remove desired “knock out” to route utility power input and camera power output leads 
into the enclosure. Mount the PS1 in the desired location using the four screw holes on the 
mounting bracket.   
 
4. 

Power Leads 

The blue wire leads on the transformer are to be connected to 120 volt, utility power. One 
blue lead is connected to the fuse holder. Connect the fuse holder lead and one blue lead to 
main utility hot and neutral leads. Connect the utility ground (green) lead to the ground lug 
on the chassis. Connect the red, 24 volt output, leads to the camera.  
 
5. Replace front panel and secure with the 4 screws provided. 
 
6. 

Fuse Replacement 

– Always turn off power to the PS1 before replacing the fuse. Use a 

maximum 1 amp fuse in the PS1-24.  

 

TROUBLE SHOOTING 

Before trouble shooting this power supply disconnect the power. If  there is no power output check the 
fuse and power connections, both input and output.   

 

REPAIR 

Should your PS1 need service contact Juice Goose for assistance and authorization to return the unit. 
PLEASE NOTE: a return authorization number is required in order for the service personnel to correctly 
and promptly identify, repair and return your unit. 
 
You may obtain a Return Authorization Number  by calling: 713-772-1404 or sending email to 
[email protected].

 

DIMENSIONS (INCHES) 

6.0 x 6.0 x 4.0 

WEIGHT (LBS)  

POWER INPUT 

120 VAC, 60Hz 

POWER OUTLETS 

RED WIRE LEADS 

CURRENT CAPACITY  

.75 Amps @ 120 VAC 

3.75 AMPS @ 24 VAC  

CURRENT OVERLOAD PROTECTION 

1 AMP MASTER CIRCUIT  

CHASSIS DESIGN 

 NEMA 1 METAL ENCLOSURE 

CHASSIS FINISH 

POWDER COAT ENAMEL – TAN 