Maintenance

7.

Maintenance

ATTENTION

(See chapter on “Safety information and
dangers due to non-compliance”)

Always observe the chapter on “Intended
Use”!

7.1

Cleaning

ATTENTION

(See chapter on “Safety information and
dangers due to non-compliance”)

Only use clear, clean drinking water to
clean the housing and transparent filter
cover.

Domestic all-purpose cleaners and glass
cleaners can contain up to 25% solvents or
alcohol (spirits).

These substances can chemically attack the
plastic parts, which can lead to brittleness or
even fractures.

Such cleaners must therefore not be
used.

8.

Warranty and Services

In order to comply with the legal warranty
claim, according to DIN 1988, Part 8, it is
necessary that the "… backwashing takes
place at least every 2 months, after operat-
ing conditions exist … ".

Further, an annual "… check of the set
discharge pressure at the pressure gauge
(visual check) when no water is flowing and
at the peak flow (large amount drawn off) …
" is necessary.

Regular servicing is indispensable in order
to continue to achieve a successful process
for many years after the unit is put into serv-
ice. In the building services sector this is
covered by DIN 1988, Part 8.

A servicing agreement is the best way to en-
sure a good operating function beyond the
warranty period. 

Wherever possible, the regular servicing
work and supply with consumables and
wearing materials, etc. should be carried out
by the specialist trade or the factory’s cus-
tomer service department.

Содержание GUBi-E

Страница 1: ...n before installing and putting the unit into service These must always be issued to the owner user Extended warranty peri od if a service agreement is concluded Installation and Operating Instruction...

Страница 2: ...permitted with special approval Dear Customer Thank you for the confidence you have shown in us by purchasing this unit With this Domestic Water you have purchased a state of the art unit This Domesti...

Страница 3: ...must be permanent ly available at the place in which the Domes tic Water is used This instruction manual is intended to make it easier to familiarize yourself with the Domestic Water and its possible...

Страница 4: ...nd dan gers due to non compliance In detail failure to observe the general dan ger symbols can result for example in the following risks Failure of important functions of the Domestic Water Danger to...

Страница 5: ...supplier must always be consulted before using the Domestic Water outside the use limitations given in the in struction manual The Domestic Waters are only to be used in a technically perfect conditi...

Страница 6: ...ns for drinking water installations in ac cordance with DIN 1988 They are tested by the DVGW Deutsche Vereinigung des Gas und Wasserfaches e V technical scientific association for the gas and water in...

Страница 7: ...m where the unit is installed must be dry and frost free Unauthorised persons must not have ac cess to the Domestic Water ATTENTION See chapter on Safety information and dangers due to non compliance...

Страница 8: ...age can result the pipe may burst or the built in rotary flange can break This can re sult in major water damage In this case people close to the Domestic Water are exposed to a health risk due to the...

Страница 9: ...er can be fed several metres to the next wastewater connection either through a hose or a pipe to be fitted to the flushing water valve This pipe must have the same dimension as the flushing water val...

Страница 10: ...vented by means of backwashing see chapter Di scharging the backwashing water After backwashing and venting the Do mestic Water station is ready for use 5 2 Pressure setting Change the factory set pr...

Страница 11: ...ed dirt from the fine filter screen The backwashing takes place at full tap wa ter system pressure To clean the screen the backwashing handwheel 9 is turned in an anti clockwise direction up to the li...

Страница 12: ...om high water consumption this can also cause water damage especially if the backwash ing water is not discharged as described in the chapter Discharging the backwashing water 5 4 1 Backwashing interv...

Страница 13: ...n and dangers due to non compliance Only original spare parts are to be used Independent modifications and changes are prohibited for safety reasons These can im pair the function of the Domestic Wate...

Страница 14: ...d leak tightness only approved persons may open the units and replace parts subject to water pressure Help with faults Fault Cause Remedy Backwashing water con tinues running Flushing valve not fully...

Страница 15: ...the legal warranty claim according to DIN 1988 Part 8 it is necessary that the backwashing takes place at least every 2 months after operat ing conditions exist Further an annual check of the set disc...

Страница 16: ...sure class according to which the Domestic Wa ter must fulfil the requirements to DIN 19632 The maximum operating pressure is lower in order to ensure the optimum func tion of the Domestic Water The b...

Страница 17: ...1 x Built in rotary flange JQE 1 or 1 with bayonet fixture and screw con nection 9 6 Accessories JUDO JQR expansion quickset Order no 8250041 for the series connection of two devices e g filter and w...

Страница 18: ...18 JUDO GUBi E Spare Parts JGB E 1 10 Spare Parts JGB E 1...

Страница 19: ...10390 20 9 Display button 1 1120424 2 10 Profile flange seal 2 1200218 5 11 Cylinder screw M6 x 25 coated 4 2010199 2 12 Sieve 1 2150015 68 13 Suction Pipe Gasket 1 1607410 3 14 Self tapping screw 1 1...

Страница 20: ...fo judo online be www judo online be JUDO Austria Zur Schleuse 5 A 2000 Stockerau Tel 43 0 2266 6 40 78 Fax 43 0 2266 6 40 79 e mail info judo online at www judo online at Installed by JUDO BIOQUELL S...

Отзывы: