background image

Operation

The degree of contamination and cleaning

process can be observed from the outside.

INFO_NO_HEADER

The device is backwashed with

filtered water. The filtered water

supply of the domestic installation

remains intact during the backwash-

ing process. No dirty water can reach

the pure water side during the back-

washing.

4.2.1 Backwashing interval

If cleaning is not performed soon enough,

the result may be damage to the sieve

insert. Large quantities of filtered particles

can deform the sieve fabric and in extreme

case lead to tearing of the sieve fabric.

In addition, larger deposit quantities can

impair the backwashing function mechani-

cally.
According to DIN EN 13443-1 backwashing

the device is required at the latest every six

months.

The manufacturer recommends a back-

washing:

at least every 2 months

if the water pressure drops

if the filter is visibly dirty

Experience has shown that new installa-

tions in the early stages of installation lead

to increased dirt deposits. In this case, a

more frequent backwashing is necessary.

4.2.2 Due date of backwashing

Every two months, a beep reminds you that

the backwashing is due.
To switch off the beep, press the reset but-

ton on the handwheel cover.

By pressing the button, the time interval

of 2 months is restarted.

The signal is just an additional reminder

of the necessary backwashing. Indepen-

dant from this signal, the backwashing

interval indicated in chapter 4.2.1 must be

observed.

Check backwash reminder alarm

Press the reset button for at least 3 sec-

onds:

Beep:

 the backwash reminder alarm

works. The batteries still have enough

capacity.

No beep:

 replace the batteries by new

leak-proof batteries.

This battery test has no influence on the

backwashing interval.

Replace batteries of the backwash

reminder alarm

1.

Remove the handwheel cover.

2.

Replace the batteries in the battery

compartment by new ones of the same

type (AAA or LR03).

3.

Refit the handwheel cover.

4.

Press the reset button on the hand-

wheel cover for at least 3 seconds. The

time interval of two months is restarted.

Attention:

 do not dispose of used batter-

ies with the household waste, but in accor-

dance with the local waste disposal regula-

tions.

12

JUDO JPM+ 

1702272 • 2020/07

Содержание 8170200

Страница 1: ...Installation and operating instructions JUDO PROMI PLUS Domestic water station 1 Valid for EU countries and Switzerland Language English Read before use and store...

Страница 2: ...rinting even in excerpt form is only permitted with special approval Dear customers Thank you for the confidence you have shown in us by purchasing this prod uct You have purchased a state of the art...

Страница 3: ...tallation of the device 9 3 4 Draining of the backwash water 10 3 5 Commissioning 11 4 Operation 11 4 1 Setting the downstream pres sure 11 4 2 Cleaning of the sieve insert backwashing 11 4 3 Conversi...

Страница 4: ...omply with the European Drinking Water Directive 98 83 EC Before using the device with water that does not comply with this Direc tive it is essential to consult the manufac turer 1 2 2 Water pressure...

Страница 5: ...rotary flange fitting must be fitted so that it is free from mechanical stress or strain Otherwise mechanical damage to the pipe or the rotary flange fitting up to and including breaks can result For...

Страница 6: ...to the device e g Direction of flow arrow Type label Cleaning information must be observed and maintained in legible condition 1 5 Units used Unit Conversion bar 1 bar 105 Pa 0 1 N mm2 DN 20 1 DN 25...

Страница 7: ...f the pressure reducer 10 Inlet pressure gauge 11 Outlet pressure gauge 12 Outlet backwash water 2 3 Materials used The materials used are resistant to the physical chemical and corrosive loads expect...

Страница 8: ...test according to DIN EN 13443 1 and DIN 19628 and are therefore not permitted to wear the approval mark 3 Installation CAUTION The device may only be installed by qualified technical personnel Insta...

Страница 9: ...ce CAUTION If no bypass valve is installed a shut off valve must be installed upstream and downstream of the unit in order to interrupt the water supply during installation mainte nance repair or malf...

Страница 10: ...of the wastewater can be drained simulta neously If a wastewater connection directly beneath the device is not possible the backwash water can be drained away via a hose or a pipe that is connected fr...

Страница 11: ...ia the pressure reducer The factory pre set downstream pressure of 4 bar can be changed to a value between 1 5 bar and 6 bar depending on the upstream pressure 1 Undo the countersunk screw on the hand...

Страница 12: ...a more frequent backwashing is necessary 4 2 2 Due date of backwashing Every two months a beep reminds you that the backwashing is due To switch off the beep press the reset but ton on the handwheel c...

Страница 13: ...ts WARNING The device may only be repaired by qualified technical personnel Only use original spare parts for repairs Before performing work on the device that goes beyond pure operational use the dev...

Страница 14: ...the flange surfaces against damage to ensure proper sealing Protect the device from dirt so as not to impair drinking water hygiene Store the device in a frost free place to prevent damage caused by...

Страница 15: ...line cracks on the filter bowl Filter bowl was exposed to high temperatures or solvents Inform the installer or the closest customer ser vice point If water escapes close shut off valves Have the filt...

Страница 16: ...ecked annually on the outlet pressure gauge both at zero flow and at peak flow large withdrawal If necessary the setting of the outlet pressure must be readjusted To ensure the process operates succes...

Страница 17: ...bar 1 5 bar 6 bar Factory setting of downstream pressure 4 bar 4 bar 4 bar Mesh size sieve insert2 100 m 0 1 mm 100 m 0 1 mm 100 m 0 1 mm Water temperature and ambient temperature max 30 C max 30 C m...

Страница 18: ...th of the device C Height above the pipe middle D Height below the pipe middle E Installation depth up to the pipe middle F Waste water connection up to the pipe middle G Waste water nominal diameter...

Страница 19: ...Technical data 7 3 Spare parts 1702272 2020 07 JUDO JPM 19...

Страница 20: ...r alarm consisting of pos 1 2 3 1 2010495 49 1 Handwheel lid 1 2 Backwash reminder alarm 1 3 Battery 1 5 V Typ AAA set with 2 pcs 1 2060347 8 4 Countersunk screw M5 12 1 5 Disc A 6 4 1 6 Memo handwhee...

Страница 21: ...sieve 1 33 O ring 25 3 5 1 34 O ring 52 3 5 1 35 Cylinder screw M6 25 Set with 4 pcs 1 2060333 2 36 Pressure gauge seal 2 37 O ring 14 5 2 5 4 38 Pressure gauge connection piece 2 39 Pressure gauge 0...

Страница 22: ...recycling system To protect environment old appliances and used batteries must not be disposed of with household waste Instead use the local col lection and return points which are commit ted to free...

Страница 23: ...Maintenance log 9 Maintenance log Product designation Domestic water station Order number Serial number Date Work activities performed Company signa ture 1702272 2020 07 JUDO JPM 23...

Страница 24: ...judo online ch judo online ch BENELUX JUDO Wasseraufbereitung GmbH Filiaal Filiale Benelux Laarbeeklaan Av du Laerbeek 72 A1 B 1090 Brussel Bruxelles Phone 32 0 24 60 12 88 Fax 32 0 24 61 18 85 E mai...

Отзывы: