Professional Wideband True Diversity System (75MHz)
43
3.Sensitivity
(1) Press
▲、▼
to “3. Sensitivity.”Press SET to enter into the
setting screen.
(2) Press
▲、▼
to adjust the sensitivity. Use 3 dB as unit modi-
fication. After adjustment, press SET to save the setting; the range of
sensitivity is -15dB~+15dB.
4. Low Cut
Press
▲、▼
to “4. Low Cut”Press SET to enter into the setting
screen.
Press
▲
: Turn off the Low Cut function.
Press
▼
: Turn on the Low Cut function.
After adjustment, press SET to save the setting.
5. Device ID
(1) Press
▲、▼
to select “5. Device ID .” Press SET to enter into
the setting screen.
(2) Press
▲、▼
to adjust the device ID. The range is from 0 ~ 255.
After the adjustment, press SET to go to ID setting: On / Off
Press
▲
: ON , The ID of the microphone and the ID of the receiver
shall be the same as to use the REMOSET function.
Press
▼
: OFF , Ignore the ID value. The microphone will receive all
REMOSET information transmitted by“receivers with ID code”
Press SET to save the setting.
1. Frequency
2. Group/Channel
3. Sensitivity
4. Low Cut
Sensitivity
0 dB
1. Frequency
2. Group/Channel
3. Sensitivity
4. Low Cut
Low Cut
Off
Low Cut
ON
5. Device ID
6. Remoset
7. RF Power
8. Contrast
0
Device ID
ID : OFF
0
Device ID
ID :
OFF