9. PRESSURE PAD
9-1 The purpose of the Pressure pad is to insure that the Terminal stays in the correct
position over the anvil when the Feed finger is moving backwards, the pressure on the
terminal can be adjusted by either tightening or loosening the 2 x M5 adjustment
screws as shown below.
10. Terminal Feed Position
10-1 When you receive the applicator the feed will be factory set, however if you do
need to make an adjustment, please ensure that the press is switched off and the
applicator is removed from the Press.
Note: The function of this adjustment is to ensure that the terminal is in the correct
position when crimped. See section 16.
10-2 To adjust the position of the Feed finger loosen the M5 screw in the lever block
(124), then carefully loosen the Ring nut (125). Once these 2 parts have been loosened
you can adjust the position of the Feed finger by rotating the Adjusting bolt (123),
clockwise to take the terminal forward and anti-clockwise to bring the Terminal back.
When you have assumed the correct position carefully tighten the Ring nut (125) then
the M5 screw.
Now you can place the applicator back into the press and carefully rotate the Press by
manual operation to see if the correct position has been achieved (See section 15).
If the crimped terminal is not correct then repeat this process.
10-3 The terminal position will vary if the Pitch screw is adjusted (section 8).
Please see the following page for the exploded view of this section.
M5 adjustment Screw
M5 Locking nut
Spring
Pressure Pad
M5 Spring Block