Selection of Proper Dies
Female Die
Male Die
Applicable Nominal Applicable
Female
Die Male
Die
Terminals
Size
Wire Range
(mm sq.)
8 6.64~10.52
TD-221 TD-211
Non-insulated 14
10.52~16.78
TD-222
TD-211
Terminals and
22
16.78~26.66
TD-223
TD-212
Splices 38
26.66~42.42
TD-224
TD-212
(Butt type,
60
42.42~60.57
TD-225
TD-213
Parallel type)
70
60.57~76.28
TD-226
TD-213
80
76.28~96.3
TD-227
TD-214
100
96.3~117.2
TD-228
TD-214
150
117.2~152.05
TD-229
TD-215
Note: Applicable wire range for parallel type non-insulated slices denotes the
total cross sectional areas of the wires to be used.
1. Choose the correct terminal and wire combination.
2. Choose the correct male and female dies from the chart above to match the nominal size
terminal to be used. The dies are clearly marked with the die number.
CAUTION: SELECTING THE WRONG COMBINATION OF DIES COULD DAMAGE THE
DIES OR THE TOOL ITSELF.