Cable Thermocouple Temperature Sensors for Plastic Industry T1565

3.1 Application

Cable  thermocouple  temperature  sensors  T1565  with  cable 
connecting line (firmly connected) are designed for tempera-
ture  measurement  at  devices  for  plastic  industry  and  similar 
applications.

3.2 Description

A single thermocouple sensor type “J“ or “K“ is placed in the 
stem  of  measuring  insert.  The  stem  continues  by  stainless 
steel spring with extended termination. Position of the bayonet 
cap is adjustable through the entire length of the spring. Sen-
sors are mounted into the bore by bayonet cap and by optional 
connecting pipe union, which can be also supplied.

4. Installation, operation and maintenance
4.1 Installation and commissioning

4.1.1 General

Sensors are connected directly to the decoding device or to the 
terminals of associated cabinet.

4.1.2 Commissioning

The  sensor  is  ready  for  operation  after  connection  of  the 
connection wires to the terminals of the associated apparatus.

Thermocouple “K“            Thermocouple “J“

GN - green, BK - black, WH - white

4.1.3 Electrical connection

4.2 Operation and maintenance

Sensors do not need any maintenance.
It  is  recommended  to  check  the  mounting  of  the  sensors  at 
preselected intervals.
To  ensure  metrological  parameters  of  the  sensors,  periodic 
checks  of  calibration  parameters  must  be  performed.  Period 
of calibrations is set by the user and it is based on operating 
conditions and internal metrology regulations. Manufacturer’s 
recommended  period  is  12  months.  If  there  is  during  the 
calibration  found  difference  from  the  expected  metrological 
parameters, it is necessary to replace the sensor.

• Thermocouple 1x “J“, “K“.
• Measuring range -50 to +800 °C.
• Accuracy class 1, 2 acc. to EN 60584-1.
• Insulated measuring junction.
• Stem diameter 6 and 8 mm, peak angle 120°.
• Stem material stainless steel 1.4401.
• Full stainless steel design.
• Adjustable suspended bayonet cap 15 to 190  
  mm with inner diameter 12.2 to 15.2 mm / 2 slots.
• Optional length, insulation and wiring termination.
• Optional connecting pipe union.
• Housing up to IP 67.

T1565

Cable Thermocouple Temperature Sensors 

for Plastic Industry

3. Product description

L2

200

AL

L

L1

120°

ØD

ØD2

ØD1

NB1

NB2

NB5

NB4

WH

WH

GN

BK +

-

+

-

WH

WH

GN

BK +

-

+

-

Содержание T1565

Страница 1: ...measuring junction Stem diameter 6 and 8 mm peak angle 120 Stem material stainless steel 1 4401 Full stainless steel design Adjustable suspended bayonet cap 15 to 190 mm with inner diameter 12 2 to 15...

Страница 2: ...1 6 Installation and commissioning 3 1 7 Spare parts 3 1 8 Repairs 3 1 9 Warranty 3 2 End of service and disposal 3 2 1 End of service 3 2 2 Disposal 3 3 Product description 4 3 1 Application 4 3 2 De...

Страница 3: ...tenance follow the instructions in chapter 4 1 7 Spare parts Any of the compact parts of the product can be also ordered as a spare part if there are not required special procedures or technological o...

Страница 4: ...ermocouple J GN green BK black WH white 4 1 3 Electrical connection 4 2 Operation and maintenance Sensors do not need any maintenance It is recommended to check the mounting of the sensors at preselec...

Страница 5: ...related to the initial calibration of the sensor To ensure accuracy of measurement it is necessary to calibrate sensors periodically according to the operating parameters Sensors can be supplied with...

Страница 6: ...24 Flat connector for single sensor plug mini version ceramic up to 650 C 09 Other OPTIONAL ACCESSORIES Code Calibration in customer defined points including certificate of calibration KTE32AA Thermoc...

Страница 7: ...JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Отзывы: