JSP FlexiTEMP 60 Скачать руководство пользователя страница 8

- 8 -

Flexible Sheath Resistance and Thermocouple Temperature Sensors FlexiTEMP

®

 60

TC with head MA

BK  - black
GN  - green
PK  - pink

4.1.5 Examples of mounting of the sensors in 
operation

Sensors without thermowell, respectively protective tube, 
fixing shift pipe union

4.2 Operation and maintenance

The products do not need any operation and maintenance.
It  is  recommended  to  check  the  mounting  of  the  sensor  at 
preselected intervals.
To  ensure  metrological  parameters  of  the  sensors,  periodic 
checks  of  calibration  parameters  must  be  performed.  Period 
of calibrations is set by the user and it is based on operating 
conditions and internal metrology regulations. Manufacturer’s 
recommended  period  is  12  months.  If  there  is  during  the 
calibration  found  calibration  difference  from  the  expected 
metrological parameters, it is necessary to replace the sensor.

5. Product specifications

5.1 Technical specifications

Resistance sensors type

 T1060

Measuring resistor (RTD):

 

1xPt100, accuracy class A, B according to EN 60751

 

inside wiring: two-wire, four-wire, outer diameter of stem 

 

3 and 6 mm

 

2xPt100, accuracy class A, B according to EN 60751, 

 

inside wiring: two-wire, three-wire, four-wire, outer  

 

diameter of stem 3 and 6 mm 

Measuring range:

 

-200 to +700 °C (accuracy class B)

 

-100 to +450 °C (accuracy class A)

Measuring current:

 

recommended  

0.1 to 1.0 mA

 

maximal 

 

3 mA

Output signal:

 

resistance

Electrical insulation resistance:

 

min. 100 M

 according to EN 60751,  

 

at temperature (20 ±15)°C, max. 80 % relative humidity

Thermocouple sensors type T1560

Thermocouple (TC):

 

1x / 2x “J“, “K“, “N“, 

 

 

accuracy class 1 (not for type N with code KV), 2    

 

according to EN 60584-1, EN 60584-3

Measuring range:

 

-200 to +800 °C (“J“)

 

-200 to +1300 °C (“K“, “N“)

Output signal:

 

voltage

RD

RD

RD

RD

RD

+

BK

+

GN

+

PK

+

BK

BK

+

+

GN

GN

+

+

PK

PK

+

RD

RD

RD

RD

RD

+

BK

+

GN

+

PK

+

BK

BK

+

+

GN

GN

+

+

PK

PK

+

1xJ

2xJ

1xK

1xN

2xK

2xN

Содержание FlexiTEMP 60

Страница 1: ...600 Nicrobell Pyrosil Sheath diameter from 1 to 6 mm Optional nominal length L 0 1 to 50 m Fast response to temperature changes Flexible stem Optional version of cold junction with flying leads conne...

Страница 2: ...ct description 4 3 1 Application 4 3 2 Description 4 3 3 Dimensional drawings 5 4 Installation operation and maintenance 6 4 1 Installation and commissioning 6 4 2 Operation and maintenance 8 5 Produc...

Страница 3: ...s Sensors with fiberglass insulation of wires must be stored in a dry environment 1 6 Installation and commissioning During installation commissioning operation and maintenance follow the instructions...

Страница 4: ...with the sheath made of stainless steel 1 4404 for resistance sensors 1 4541 for thermocouple J or Inconel 600 2 4816 Nicrobell Pyrosil for thermocouple K and N Resistance sensors are supplied with si...

Страница 5: ...zalit mi v vody dle NAMUR S2 S3 S4 p evodn k H1 hlavice p ipojovac rouben 42 M4 33 L D 42 M4 33 L D L 50 33 D L 62 33 D G1 2 G3 8 44 33 30 8 M4 Parametry proveden krytu dle po adavku instalovan ho p...

Страница 6: ...nce has not been lowered 4 1 3 Special conditions for safe use of sensors in Intrinsically safe version code EI 1 Temperature sensors in intrinsically safe version code EI can be connected to intrinsi...

Страница 7: ...Max temperature of measured medium T1 450 C 440 C T2 300 C 290 C T3 200 C 195 C T4 135 C 130 C T5 100 C 95 C T6 85 C 80 C For process temperature measured medium 440 C Tm 1200 C the maximal surface te...

Страница 8: ...cal parameters it is necessary to replace the sensor 5 Product specifications 5 1 Technical specifications Resistance sensors type T1060 Measuring resistor RTD 1xPt100 accuracy class A B according to...

Страница 9: ...rmocouple wires Steel sheath Hot junction Ceramic insulation Thermocouple wires Steel sheath Ceramic insulation Hot junction Steel sheath Thermocouple wires Ceramic insulation Hot junction Flat connec...

Страница 10: ...nsmitter 44 mm span of fixing screws M4 33 mm Applicable transmitters For range of transmitter see category optional accessories in transmitters for head mounting and the catalogue transmitters For ap...

Страница 11: ...00 C 520 C 1020 C 1100 C S61 4 5 only for TC 620 C 1100 C S71 6 600 C 720 C 1100 C 1200 C S99 Other Code Nominal length of stem L mm L Fill length in mm min length 100 mm Code Cold end version of stem...

Страница 12: ...or PK1 Lock anti pull up cable for standard connectors for single sensor PK2 Lock anti pull up cable for standard connectors for double sensor PK3 Lock anti pull up cable for mini connectors for singl...

Страница 13: ...meter sheath 3 to 6 mm M04 M20x1 5 only for sensors with diameter sheath 3 to 6 mm M05 M12 only for sensors with diameter sheath 3 to 6 mm only for shift pipe union PB G01 G1 8 only for sensors with d...

Страница 14: ...14 Flexible Sheath Resistance and Thermocouple Temperature Sensors FlexiTEMP 60 8 Appendix 8 1 Declaration of conformity explosion hazard environment version codes EI...

Страница 15: ...JSP s r o Raisova 547 506 01 Ji n Czech Republic 420 493 760 811 export jsp cz www jsp cz Your Supplier...

Отзывы: