![JS Automation LSI-3104 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/js-automation/lsi-3104/lsi-3104_user-manual_2028622025.webp)
24
15.5
REGISTERS CONCERNING EXTERNAL TRIGGER AND DATA ACCESS(X AXIS)
Address of register
:
0009H ----- EXTERNAL TRIGGER LATCH ENABLE
=======================================================================
Return/Command
:
(READ/WRITE )
0000H--> External trigger latch disable.
0001H--> External trigger latch enable. (default)
Comment
:
While register 000AH (EXTERNAL TRIGGER LATCH/LOAD MODE) has been set
to 1 or 2
,
and the external trigger/load occurred this register value will be reset to "0".
Address of register
:
000AH ----- EXTERNAL TRIGGER LATCH/LOAD MODE
=======================================================================
Return/Command
:
(READ/WRITE )
0000H-->Continuous external trigger latch (counter)mode.(default)
0001H-->One shot external trigger latch mode. Once triggered the register
0009H(EXTERNAL TRIGGER LATCH ENABLE) will be reset to "0".
0002H--> Continuous external trigger load (counter) mode.
0003H--> One shot external trigger load mode. Once triggered the register
0009H(EXTERNAL TRIGGER LATCH ENABLE) will be reset to "0".
。
Address of register
:
000BH ----- EXTERNAL TRIGGER LATCH/LOAD FLAG
=======================================================================
Return
:
(READ ONLY )
0000H-->Latch/load has not been occurred.
0001H-->Latch/load has been occurred. (Once read
,
the value will be reset to "0")