©JRI
5
To ensure your safety during installation or intervention on a device at this height (2m), use a
stable means to and in good used condition, wear suitable footwear and non-slippery and
install security markup if intervention takes place in a place of passage.
c)
Installation of wall-mounting bracket
The bracket can be fixed thanks to its adhesive plaster or it can be screwed.
Screwing map
IV.
LEDS’ INDICATIONS
General
=
ModeM-PC dialog
Instantaneous reading
= 1 Flash during reading
=
Radio communication
Standby
Upload memory
=
1 Flash every seconds
=
Fast flashing along the
transfer duration
V.
CHARACTERISTICS
Radio band
868MHz or 902MHz*
Operating range
-40°C +85°C
Storage conditions
-30 + 70°C / 0-90% not condensed
Emitting power
25 / 500mW
power supply
9VDC / 0,3A**
Relay output
30VDC – 1A
Dimensions 123x69x30mm
CE ERM FCC conformity
EN 301 489 / EN 61000 / EN 61010 EN 55022 / EN 300 220
FCC conformity
FCC part 15*
*
Only for Spy RF USB ** Included for Europe market