Operation
Operating instructions
54
If the displayed value is outside the flow rate
limits, adjust it using the regulating valve (1).
The system produces until the Anolyte level
sensor sends a full level message, and
production resumes automatically when this
message is cleared.
10.4
Switching off the system
On the control panel, turn the Production rotary
switch to the Stop position.
The current production is stopped.
Check whether the PLC (1) display shows the
following message:
If a different message appears, refer to Chapter
12 „Troubleshooting“ 65.
On the control panel, turn the main switch to
the 0 = OFF position.
The power supply is turned off.
Please note! After completing disinfection, the
mobile Hycleen Des 30 system must be made
storable (salt-free). For this purpose, the
system must be descaled and rinsed with water.
In addition, also make sure to store the reactor
wet.
See Chapter 10.5 “Decommissioning during
prolonged periods of non-use (downtime > 3
days)“ on page 55.
Sterisol
v1.0
Pump 1
Nx 1
1
Содержание 9800.002