System Overview 

The system includes a touch-screen control station, (which may be a fixed-position wall-mount or a portable 

pendant), motorized winches, each with limit switches and encoder, and electronic motor controls.   The system 

permits the operator to specify the winch target.  In variable-speed applications, the operator may also specify the 

winch operating speed, acceleration time, and deceleration time.  These parameters may be entered "on the fly", 

or may be recorded as Presets, for later playback. 

CONTROL SYSTEM 

Each winch motor is connected to its electronic motor controls.  These connections include wiring to the motor, 

motor brake, winch limit switch, and motor encoder.  The electronic motor controls for each winch may be housed 

in an individual starter cabinet, or grouped together with others in motor control center cabinets (MCC's).  

The electronic motor controls are connected through network wiring to a logic cabinet, which houses the 

programmable logic controller (PLC).  The PLC is a dedicated-purpose industrial computer.  The PLC gathers 

data from the electronic motor controls and issues commands to them.  The logic cabinet also contains power 

supply for the system power and emergency stop system.  In fixed-position wall-mount systems, the system 

control panel is located on the face of the logic cabinet.  In systems operated through a portable control pendant, 

the control pendant receptacle may be located on the logic cabinet, or at a remote location. 

 

System Components 

EMERGENCY STOP SYSTEM 

The Emergency Stop system is operated through latching mushroom-head Emergency Stop buttons in the control 

system.  These are located as required throughout the performance space.   The E-stop buttons are joined in a 

series loop; pushing any of the buttons will break the loop, and signal an emergency stop condition.   

Pressing an E-stop button will immediately stop all motors in the system, by turning off the control power to each 

winch starter.  Pressing the emergency stop button will also signal the PLC that an emergency stop condition 

exists. The Emergency Stop buttons latch when pressed; to release a non-illuminated E-stop button, turn the 

button one-quarter turn clockwise (as indicated by arrows on the button) and allow the button to pop out. 

MOTOR STARTERS 

Each winch axis includes a starter, which contains circuit protection and electronic motor control devices.  In 

variable-speed winches, each starter includes a vector inverter drive, which takes in data from the motor encoder 

and winch limit switches, provides motor power and brake release signals, and communicates with the 

programmable logic controller.  The vector inverter drive incorporates motor protection functions, including 

overload sensing, and provides fault status information.  Fixed-speed starters include a remote I/O system and 

reversing starter with circuit and motor overload protection. 

 

Содержание SCENECONTROL 100

Страница 1: ...ture and Installation of Theatrical Equipment Worldwide 315 451 3440 Fax 315 451 1766 www jrclancy com Rev 3 October 7 2009 SceneControl 100 Motorized Rigging Control System Operating Instructions 2009 J R Clancy Inc ...

Страница 2: ... STARTERS 2 LIMIT SWITCHES 3 End of travel limits 3 Limit switch types 3 WALL MOUNT CONTROL STATION 3 PORTABLE CONTROL PENDANT 4 System Operation 5 BASE SCREEN MULTIPLE WINCH SYSTEMS 5 WINCH BASE SCREEN 5 WINCH OPERATION DIRECT CONTROL 6 WINCH OPERATION TARGET CONTROL 7 RECORDING PRESETS 7 STATUS PAGE 8 PARAMETER PAGE 9 LOAD SENSE PARAMETERS PAGE 10 Load Learning 11 SYSTEM PRESETS PAGE 12 SYSTEM P...

Страница 3: ...ature of theatre could such instructions be possibly written it is intended to provide a guide to the safe and efficient operation of the furnished stage equipment and its routine maintenance No manual can replace constant vigilance and common sense A routine maintenance schedule should be established and followed and appropriate records should be maintained Learn the feel sound and even the smell...

Страница 4: ...systems the system control panel is located on the face of the logic cabinet In systems operated through a portable control pendant the control pendant receptacle may be located on the logic cabinet or at a remote location System Components EMERGENCY STOP SYSTEM The Emergency Stop system is operated through latching mushroom head Emergency Stop buttons in the control system These are located as re...

Страница 5: ...mechanism Each rotary limit switch has four elements up overtravel up down and down overtravel Direct struck limit switches are struck by a piece of the driven mechanism e g a moving drum flange or a cam mounted on the counterweight arbor cable clew or lift guide WALL MOUNT CONTROL STATION The SceneControl 100 wall mount Control Station is the main control point for the motorized rigging system It...

Страница 6: ...used to control motion rather than the panel mounted pushbuttons The upper left button is GO UP the button immediately below that is GO DOWN and the bottom button on the left side is GO TARGET These button operate in Deadman mode just like the panel mounted pushbuttons the buttons must be pushed and held to initiat the button will cause the move to stop In systems where there are both a wall mount...

Страница 7: ...the keypad the new value will be transferred to the TARGET field and the keypad will close shows whether load sensing is on or off for that winch The function of the SYSTEM PRESET PAGE button is covered in a later section of this manual If the Scenecontrol 100 is set up selection page is needed WINCH BASE SCREEN Each winch controlled by the system has a base screen associated with it An area at th...

Страница 8: ...rn to the winch selection page WINCH OPERATION DIRECT CONTROL When a winch base screen is opened up the current position is displayed in the POSITION and TARGET fields and the default speed is displayed in the SPEED field variable speed winches only To run the winch up or down from this point push and hold the GO UP or GO DOWN button on the control station The winch will accelerate to the default ...

Страница 9: ...he desired target and speed on the motor base screen as described in the previous section Next open the Preset Record screen by touching the PRESET RECORD touchbutton on the winch base screen Preset recording is a password protected function If a password is not currently active the login screen will pop up prompting you to enter a user name and password using the on screen keyboard Design Manufac...

Страница 10: ... the motor brake is released winch in motion grey when it is applied winch stopped UP LIMIT Red when the winch is on the up limit switch green if it is not on the limit DOWN LIMIT Red when the winch is on the down limit switch green if it is not on the limit FAULT WARNING Red when there is a drive fault or warning grey otherwise In case of a fault the drive must be reset before it can be reference...

Страница 11: ...r is not logged in touching a numeric entry field will pop up the user name and password entry fields To enter the user name touch the user name field an alphanumeric keypad will appear Use this to key in the appropriate user name then press the ENTER key on the keypad Follow the same procedure in the password field to enter the password When these values are entered the display returns to the win...

Страница 12: ...ce calculated into target moves for the winch when moving up in decimal feet DN OFST d speed winches only The down offset is the stopping distance ca the winch wh wn in decimal feet NEW POS Entry field used with system level privileges to set a new position MAX SPD variable speed winches only The maximum speed of the winch in feet per minute MIN SPD variable speed winches only The minimum speed of...

Страница 13: ...ceptable variance from moment to moment during movement initially should be set to 10 to eliminate false tripping LOAD MAX Maximum load pounds The largest load imposed on the system during load learning inclu acceleration and deceleration loads cable weight pickup etc May be manually adjusted after load learning LOAD MIN Minimum load pounds The smallest load imposed on the system during load learn...

Страница 14: ... Each winches in that preset To run a system preset touch the desired preset selection button SYS P 1 through SYS P 8 When selected the system preset comment recorded with that preset will display at the top of the page SET PREVIEW touchbutton This will open the There is a green indicator next to each winch that is enabled for this system preset The positions of all winches are shown in the column...

Страница 15: ...SET NUMBER prompt A numeric keypad will pop up Key in a preset number 1 8 and press the ENTER key to enter it Next touch the field to the right of the ENTER PRESET COMMENT prompt An alpha keyboard will pop up Use this keyboard to enter a preset comment up to 16 characters long and press the ENTER key to enter it Next touch the selection buttons next to the winch names to select the desired winches...

Отзывы: