6-99
(1) Connected cable between WT and ANT port of WT adapter
(2) Connect the user terminal to PC port of WT adapter
(3) Connect the AC adapter to DC port to the WT adapter
Cable
Cable type
Ethernet cable for outdoor,straight
Range of applicable outer
diameter
φ
5.0 mm
〜
5.7mm
Cable length
50m (maximum)
Connector of both side
Shape
RJ-45
Cable connection
Straight connection
- WT : MDI
- ANT port of WT adapter : MDI-X
An Ethernet cable has eight signal lines. Four lines are
used to carry Ethernet signals. The remaining four lines are
used as power lines and LED control lines.
Interface
Interface
10BASE-T
/
100BASE-TX
Connector
Shape
RJ-45
Pin assign
Ethernet signal
(
MDI-X
)
Cable
Communication terminal
Cable connection
PC
straight
HUB
crossover
ROUTER
straight
・
Never connect your personal computer to the ANT port of the WT adapter. Doing so may
damage your personal computer.
・
The cable connecting between the WT and WT adapter carries 24 VDC for the WT in
addition to Ethernet signals. Before unplugging the cable connecting between the WT and
WT adapter, make sure to unplug the DC jack of the WT adapter to turn the power off.
Otherwise, the unit may be damaged.
・
When closing the small window, make sure that the rubber packing of the small window is
free from any foreign matter.
・
The cable connecting the WT and WT adapter is a straight cable. Wrong connection may
damage the unit.
・
The Equipment for connection to WT adapter PC-interface(RJ-45) shall be appropriate to
connect to TNV-1 circuits.
・
For the connection WT adapter to WT and a cable suitable for outdoor use shall be
installed.
Содержание NT337-XL2
Страница 1: ...0 JRC FWA SYSTEM INSTRUCTION MANUAL Rev 3 4 24 SEP 2008...
Страница 34: ...2 11 2 2 1 2 AP RFU Omni Antenna Mounting Bracket in mm Figure 2 3 Mounting Bracket...
Страница 37: ...2 14 2 2 2 2 AP RFU Sectoral Horn Antenna Mounting Bracket in mm Figure 2 6 Mounting Bracket...
Страница 38: ...2 15 2 2 3 AP IFU in mm Figure 2 7 External View of the AP IFU a...
Страница 39: ...2 16 2 2 3 1 AP IFU Nameplate Nameplate a in mm Figure 2 8 Nameplate 1 Blank non RoHS R RoHS 1...
Страница 40: ...2 17 2 2 4 WT in mm Figure 2 9 External View of the WT 60 a b c 61 190 190 d...
Страница 43: ...2 20 2 2 5 WT External Antenna Figure 2 12 External View of the WT External Antenna...
Страница 126: ...6 103 Length of PVC tape wrapping Small window Ethernetcable cable Spacer CS sleeve PVC tape 65 22...
Страница 137: ...7 114 Figure 7 2 Configure the WT master Step1 Step4 Step3 Step2 Step5 Step6...
Страница 168: ...7 145 START END PVC tape Self bonding tape Spacer Small window Length of PVC tape used for wrapping...
Страница 187: ...11 164 JRC FWA SYSTEM Instruction Manual H 7YZCM0101B Rev 3 4 24 SEP 2008...