247
9.7.2 Adjusting the scanner unit
The scanner unit has several locations that need adjustment. They are factory set and
normally need not be adjusted by the user. If it is necessary to make functional checks
during inspection or repair, make the adjustments that are explained below.
WARNING
Hi-voltage Caution
High-tension voltages of 4,000 volts or higher are present at the modulator
units (CME-307 or CME-308). The modulator unit must be accessed only by
qualified service engineers.
Inadvertent manipulation may result in severe electric shock.
1. Adjusting the AVR output voltage from the modulator
1. Adjusting the AVR output voltage from the modulator
1. Adjusting the AVR output voltage from the modulator
1. Adjusting the AVR output voltage from the modulator
(a) Place the radar unit into the transmission state (the range scale set to 12NM), connect a
VOM across J203-14PIN on the CME-307 or CME-308 and the GND terminal, and
adjust RV2 so that the output voltage reads +8 volts.
2. Adjusting the tuning indicator level of the receiver
2. Adjusting the tuning indicator level of the receiver
2. Adjusting the tuning indicator level of the receiver
2. Adjusting the tuning indicator level of the receiver
(a) If the tuning mode is set to "AUTO", reset it to "MANUAL".
(b) Tune the receiver with the range scale set to 12 NM.
9.7.3 Adjusting the display unit
The display unit has several locations that need adjustment. They are factory set and
normally need not be adjusted by the user. If it is necessary to make functional checks
during inspection or repair, make the adjustments that are explained below.
1. Adjusti
1. Adjusti
1. Adjusti
1. Adjusting the brilliance level
ng the brilliance level
ng the brilliance level
ng the brilliance level
(a) Set the brilliance level of the screen to its maximum from the [BRIL] key.
(b) Turn potentiometer R451 on the CRT monitor PCB so that no raster appears in the
non-displayable area. (Turn the potentiometer slowly since the circuit's sensitivity is
very high.)
2. Adjusting the focus of the CRT monitor screen
2. Adjusting the focus of the CRT monitor screen
2. Adjusting the focus of the CRT monitor screen
2. Adjusting the focus of the CRT monitor screen
(a) Turn potentiometer R951 on the neck PCB in the display unit so that the range rings
and video images appear most clearly.
Содержание JMA-2343
Страница 1: ...船舶用レーダ装置 JMA 2343 2344 MARINE RADAR EQUIPMENT 取扱説明書 INSTRUCTION MANUAL ...
Страница 2: ......
Страница 17: ...J JM MA A 2 23 34 43 3 2 23 34 44 4 取 取扱 扱説 説明 明書 書 日本語版 ...
Страница 30: ...14 1 4 構造 第 1 1 図 NKE 249 空中線外形図 ...
Страница 31: ...15 第 1 2 図 NKE 250 空中線外形図 ...
Страница 32: ...16 第 1 3 図 NCD 4170 指示機外形図 ...
Страница 115: ...99 9 2 3 装備ケーブルの接続 1 レドーム型空中線 NKE 249 ...
Страница 116: ...100 ...
Страница 117: ...101 2 回転型空中線 NKE 250 ...
Страница 150: ...134 ...
Страница 151: ...J JM MA A 2 23 34 43 3 2 23 34 44 4 I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L English edition ...
Страница 163: ...147 1 4 Configuration Fig 1 1 OUTLINE DRAWING OF SCANNER UNIT NKE 249 ...
Страница 164: ...148 Fig 1 2 OUTLINE DRAWING OF SCANNER UNIT NKE 250 ...
Страница 165: ...149 Fig 1 3 OUTLINE DRAWING OF DISPLAY UNIT NCD 4170 ...
Страница 249: ...233 9 2 3 Connection of cables to be assembled 1 Radome scanner unit NKE 249 ...
Страница 250: ...234 ...
Страница 251: ...235 2 Rotary scanner unit NKE 250 ...
Страница 285: ...付 付 図 図 A At tt ta ac ch he ed d F Fi ig gu ur re es s ...
Страница 290: ......
Страница 291: ......
Страница 292: ......
Страница 293: ......
Страница 294: ......
Страница 295: ......
Страница 296: ......
Страница 297: ......
Страница 298: ......
Страница 299: ......
Страница 300: ......
Страница 301: ......
Страница 302: ......
Страница 303: ......
Страница 304: ......
Страница 305: ......
Страница 308: ... 図 118 指示機回路ブロック図 Fig 118 BLOCK DIAGRAM OF DISPLAY UNIT ...
Страница 309: ......
Страница 310: ......