![JRC JAN-7201 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/jrc/jan-7201/jan-7201_installation-manual_2028283003.webp)
i
Cautions for High Voltage
High voltages, ranging from several hundreds to tens of thousands of volts, are used in
electronic apparatus, such as radio and radar instruments. These voltages are totally
harmless in most operations. However, touching a component inside the unit is very
dangerous. (Any person other than authorized service engineers should not maintain,
inspect, or adjust the unit.)
High voltages on the order of tens of thousand volts are most likely to cause instant deaths
from electrical shocks. At times, even voltages on the order of several hundred volts could
lead to electrocution. To defend against electrical shock hazards, don't put your hand into
the inside of apparatus. When you put in a hand unavoidably in case of urgent, it is strongly
suggested to turn off the power switch and allow the capacitors, etc. to discharge with a wire
having its one end positively grounded to remove residual charges. Before you put your
hand into the inside of apparatus, make sure that internal parts are no longer charged. Extra
protection is ensured by wearing dry cotton gloves at this time. Another important precaution
to observe is to keep one hand in your pocket at a time, instead of using both hands at the
same time.
It is also important to select a secure footing to work on, as the secondary effects of
electrical shock hazards can be more serious. In the event of electrical shocks, disinfect the
burnt site completely and obtain medical care immediately.
Precautions for Rescue of Victim
of Electric Shock
When a victim of electric shock is found, turn off the power source and ground the circuit
immediately. If this is impossible, move the victim away from the unit as quick as possible
without touching him or her with bare hands. He or she can safely be moved if an insulating
material such as dry wood plate or cloth is used.
Breathing may stop if current flows through the respiration center of brain due to electric
shock. If the electric shock is not large, breathing can be restored by artificial respiration. A
victim of electric shock looks pale and his or her pulse may become very weak or stop,
resulting in unconsciousness and rigidity at worst. It is necessary to perform first aid
immediately.
7ZPNA4466A
Содержание JAN-7201
Страница 2: ......
Страница 24: ...xxii CWA 246 26inch Display Unit Mount Kit Warning Label ...
Страница 25: ...xxiii CWA 245 19inch Display Unit Mount Kit Warning Label ...
Страница 27: ...xxv Warning Label Warning Label NKE 1139 1130 Radar Antenna NTG 3230 3225 Transmitter Receiver ...
Страница 28: ...xxvi Warning Label NKE 1632 Radar Antenna Warning Label NKE 2632 2632 H Radar Antenna ...
Страница 30: ...xxviii NTG 3230 Transmitter Receiver 30 kW ...
Страница 33: ...xxxi CWA 245 Display Unit Mount Kit CWA 246 Display Unit Mount Kit ...
Страница 35: ...xxxiii NWZ 207 Monitor Unit 19inch NWZ 208 Monitor Unit 26inch NQE 3167 Power Control Unit Option ...
Страница 53: ...6 9 1 System Block Diagram 6 199 6 9 2 Mechanism 6 201 6 9 3 Sentences 6 207 6 10 Troubleshooting 6 213 ...
Страница 76: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 13 ...
Страница 78: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 15 ...
Страница 80: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 17 ...
Страница 82: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 19 ...
Страница 84: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 21 ...
Страница 86: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 23 ...
Страница 88: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 25 ...
Страница 90: ...2 Installation of Scanner Unit 2 2 Installation for the specified scanner model 2 27 ...
Страница 92: ...2 Installation of Scanner Unit 2 3 Installation of Transmitter Receiver 2 29 ...
Страница 94: ...2 Installation of Scanner Unit 2 3 Installation of Transmitter Receiver 2 31 ...