The cable must be shielded and contain at least 5 twisted pairs made of bare copper and have a lead core size of
0.25mm2 or larger when the cable length is up to 100m. If a longer stretch of cable is required (up to a maximum of 200
m), use a lead core size of 0.5mm2 or larger.
Figure 6: Wiring Schematic
WH
White
Port +
BN
Brown
Port -
GN
Green
Aft +
YE
Yellow
Aft -
GY
Grey
Strb +
PK
Pink
Strb -
BU
Blue
Fore +
RD
Red
Fore -
BK
Black
GND
VT
Violet
Vinn