2.5.2.9 NMEA Settings ( NMEA SET )
The AlphaLine instrument is able to transmit NMEA sentence to the external listener.
In this software version, it only supports the sentence VBW and DDC.
Figure 43: NMEA OUTPUT
To set up the output settings, execute the following procedure:
1. In the MENU, touch the ADV SET button.
The PASSWORD screen appears.
2. Key in the password and confirm with the
√
button.
The ADVANCED SETTINGS MENU appears.
3. Touch the NMEA SET button.
The NMEA OUTPUT MENU appears, see Figure 43: NMEA OUTPUT on page 45
4.
•
Touch the + or - button to set SENTENCE to VBW, DDC or NONE.
•
Touch the + or - button to set INTERVAL to 100, 250, 500, 1000, 2000 or BY CHANGE.
•
Touch the + or - button to set PORT to OFF, UART0, UART1, UART2, UART3 or TCP.
5. Touch the
√
button when the settings are correct.
Note Please refer to Supported NMEA Sentences IEC 61162 on page 49 for more details about the
supported sentences.
45 | Operation
Содержание Alphatron Marine AlphaTurn
Страница 1: ...AlphaTurn Rate of Turn Indicator MED Installation and Operation Manual www jrc am ...
Страница 28: ...Figure 18 Indication Handling in Menu example 28 Operation ...
Страница 50: ...4 3 Mechanical Drawings 4 3 1 Mechanical Drawing MFM Figure 44 Mechanical Drawing MFM 50 Appendix A ...
Страница 52: ...4 4 1 Cable Diagram AlphaTurn Figure 45 Cable Diagram AlphaTurn 52 Appendix A ...
Страница 53: ...4 4 2 Connection Diagram AlphaTurn Figure 46 Connection Diagram AlphaTurn 53 Appendix A ...
Страница 55: ...4 5 1 Schematics AlphaLine MF Display Unit Figure 47 Schematics AlphaLine MF Display Unit 55 Appendix A ...