JR ProPo XG8 Скачать руководство пользователя страница 2

2

 

⿟ Method of setting and explanation of the each items on X-BUS MODE A.

 

ID : There are two ID exist on this application one is Main ID and second is the Sub ID. Main ID configures 
channel numbers. Sub ID configures upto maximum of 4 servos, data which can be adjusted individually. 

 

ID Change ( ID CHANGE)
It is capable to adjust the X-BUS devices through Transmitter.  Input both the own ID from X-BUS device and 
the desired ID channel to be changed.  Place the Cursor on “SET” and press the dial to finalize the setting. 

 

ID Reset (ID RESET)
It is capable to reset the X-BUS devices as initial setting through Transmitter. Set the Cursor on the “ID 
CHANGE” press the dial to finalize. “ID CHANGE” shall highlighted text reversed to be changed.  Place the 
Cursor on “SET” and press the dial to finalize the ID RESET.

 

Reverse (REVERSE)
It is capable to set the servo as reverse movement.  Set the particular servo’s Channel ID and Sub ID, Set either 
Normal or Reverse Press the dial.  Place the Cursor on “SET” and press the dial to finalize for connected device 
for accomplishment.

 

Neutral (NEUTRAL)
It is capable to set the servo neutral. Set the particular servo’s Channel ID and Sub ID, Set the cursor on “+” or 
“ - ” to change the neutral value, Place the Cursor on “SET” and press the dial to finalize for connected device 
for accomplishment.

 

Travel(TRAVEL)
It is capable to set the servo travel.  Set the particular servo’s Channel ID and Sub ID, Set the cursor on “+” or 
“ - ” to change the travel value, Place the Cursor on “SET” and press the dial to finalize for connected device 
for accomplishment.

※  These setting must be accomplish with Transmitter and Receiver being baind (Paired) together and X-BUS devices 

must be appropriately connected with both power turned on. 

Note: 

Be sure to Take off the Bind plug from the receiver bind port, other wise setting cannot be accomplished.

 

Caution Items

 

⿟ Actually operate the servos and carefully confirm the setting before flying.

Main ID on Left and Sub ID on 

Right for compliant Device 

which need to change ID.

Main ID on Left and Sub ID on 

Right for compliant Device.

Set the Cursor on the specific 

item and Press the scroll dial 

to finalize.

This is the value of the SETTING amount that 

determines how precisely the servo moves for one 

increment of increase-decrease. (similar to trim 

step) It can be set between 1% - 10% with 1% 

offering fine control and 10% coarse adjustment.

Press either “+” or “- to increase 

or decrease the numerical value 

on setting value in the center. 

XG6▋/▋XG8▋/▋XG11▋XBus▋Setup