NXU-2B Operations Manual
3-10
NXU-2B Commands:
BAUD
BCAST
CMDPORT
CONMODE
CONN
COR
CORINH
DATA
DISC
DUPLEX
ECHO
GATEIP
HANGTM
HELP
MAC
MYIP
NAME
PARITY
PASS
PORT
REBOOT
SAVE
SECURITY
SRVRIP
SRVRPORT STAT
STOP
SUBNET
TRAN
VER
VOCODER
WHAT
BOOST
RXDELAY
TXDELAY
RXLEVEL
TXLEVEL
VSENSE
Type HELP followed by a command to get help on that command.
Save changes with the SAVE command.
NOTE: If you decide that you don’t want to make any changes to the
NXU-2B settings
then you should place the NXU-2B back into the TRANSPARENT Mode. The TRAN
command should be used to do this, placing the unit back into the data mode.
3.4.3
Command Summary
This is a full list of the commands available in the NXU-2B command mode. More detail is
given on the following pages. You can get a one-line summary of each command by typing HELP
followed by the command.
BAUD <rate> - Set the serial port baud rate
BCAST <mode> - Sets the broadcast mode (0) Normal (1) Connectionless (2) Multicast
CMDPORT <port number> - Set the port used to receive telnet and WAIS commands
CONMODE <0/1> - Places unit in CLIENT (0) or Server (1) mode
CONN <IP address> - Connect this client to a server at IP address
COR <0/1/23> - Sets COR active low (0), high (1), VOX (2), or VMR (3)
CORINH <time> - Set COR inhibit time to 0, 500, 1000, 2000, 3000, or 4000 ms
DATA <7/8> - Set the serial port data bits
DISC - Break this client's current connection
DUPLEX <0/1> - Select either full duplex (0) or half duplex (1) for audio
ECHO <ON/OFF> - Enables/disables character echo to console
Содержание NXU-2B
Страница 8: ...NXU 2B Operations Manual viii blank page...
Страница 18: ...NXU 2B Operations Manual 1 10 End of Section One...
Страница 28: ...NXU 2B Operations Manual 2 10 End of Section Two...
Страница 60: ...NXU 2B Operations Manual 6 8 End of Section Six...
Страница 62: ...NXU 2B Operations Manual 7 2 End of Section Seven...
Страница 68: ...NXU 2B Operations Manual 8 6 End of Section Eight...