www.jps.com.tw
77
13.3.3 Timer3(Mono Type / Delay-On Type)
※ 13.3.3.1 Timer3:Parameter
Pr.234
Timer3:Delay-Period-Time
This parameter can be set to a timer
Delay-On / Mono-Pulse time
。
※ 13.3.3.2 Timer3:Digital Input
DIx _ Select
110,TIMER3 "START" input
※ 13.3.3.3 Timer3:Digital Output
DOx _ Select
108,Timer3(Mono Type):Q
DOx _ Select
109,Timer3(Mono Type):/Q
DOx _ Select
110,Timer3(Delay-On Type):Q
DOx _ Select
111,Timer3(Delay-On Type):/ Q
【Note】
Timer3 include two application:
1.
Mono Type Timer:
1.1
When set DIx(110)=ON,DOx(108) = ON
1.2
After Pr.234 after the set time will disable
。
※ DOx(109) = DOx(108) reverse output
2.
Delay-On Type Timer:
2.1
When set DIx(110)=ON,DOx(110) = OFF,
2.2
After Pr.234 after the set time will start
;
2.3
When DIx(110) = OFF,DOx(110) output = OFF。
※ DOx(111) = DOx(110) reverse output
T3-TIMER
DOx(108)
Q
Mono SET
Pr.234
DOx(109)
/Q
DOx(110)
Q
DOx(111)
/Q
Delay SET
Pr.234
DIx(110) T3-Input
DIx(111)
Pr.234
DOx(111)
DOx(110)
DIx(111)
Pr.234
DOx(109)
DOx(108)