Baud Rate

 

Commands

 

Return

 

9600

 

88 77 

55 00 00 AE

 

76 00 24 00 00

 

38400

 

88 77 55 00 00 2A

 

76 00 24 00 00

 

57600

 

88 77 55 00 00 1C

 

76 00 24 00 00

 

115200

 

88 77 55 00 00 0D

 

76 00 24 00 00

 

128000

 

88 77 55 00 00 7E

 

76 00 24 00 00

 

256000

 

88 77 55 00 00 56

 

76 00 24 00 00

 

 

10. 

SET IR

-

CUT FILTER

 

If

 

the SC20MPC camera is customized with IR

-

cut filter, the host can set the filter by issuing the following 

commands for day and night mode, no commands needed if the camera also comes with Spinel supplied 

infrared LED plate

 

that can control the IR

-

cut filt

er switcher automatically

, otherwise commands are needed.

 

Mode

 

Commands

 

Return

 

Day mode

 

56 00 AA 00

 

76 00 AA 00 00

 

Night mode

 

56 00 AA 01

 

76 00 AA 00 00

 

 

11. 

GET 

IMAGE

 

PROCESS

 

1. Get image command

 

2. Read image data length command

 

3. Read image data 

command

 

4. Stop capture

 

 

12.

 

Program flow chart

 

12.

1 Initialize

 

After power up, the camera will output: 

 

Ctrl infr exist 

 

User

-

defined 

 

sensor 625 

 

Init end (36 32 35 0D 0A 49 6E 69 74 20 65 6E 64 0D 0A)

 

 

 
 
 

12

.2 Get JPEG image

 

Содержание SC20MPC

Страница 1: ...serial protocol that can instruct the camera to send high resolution 160x120 to 1600x1200 JPEG images for storage or viewing The SC20MPC camera module comes in a compact form factor with a built in l...

Страница 2: ...different resolutions Image size 1600x1200 1280x960 1024x768 800x600 VGA QVQAF 160x120 Dimensions 32mm x 32mm x 28mm with lens Weight 0 3oz 9g VC0706 protocol compatible Pin Configuration and Dimensi...

Страница 3: ...automatic IR cut filter switch with spinel supplied IR illuminator Sensitivity 1250mV Lux sec Command Protocol HEX format data 1 RESET The host can reset the camera by issuing this command 56 00 26 00...

Страница 4: ...0 XX can usually range from 1 to 9 99 is the most compressed and 11 is the least compressed 8 SET BAUD RATE Default 115200bps The host can set the temporary Baud rates using this command the baud rate...

Страница 5: ...host can set the filter by issuing the following commands for day and night mode no commands needed if the camera also comes with Spinel supplied infrared LED plate that can control the IR cut filter...

Страница 6: ...com the application only supports window XP 7 8 as of now The camera needs to have RS232 output or TTL to RS232 converter to connect to the serial port of the PC or use a USB to TTL converter if the c...

Страница 7: ...issue or error please use SSCOM serial debug tool to test the camera and figure out the issue the SSCOM serial debug tool and instruction can be downloaded from our website www jpegcamera com For que...