1. Safety Instruction

Please read this manual carefully before installation, in which involves with important information about

installation

using

maintenance and safety.

Any undefined operations under this manual is not allowed, incorrect using may damage the product

even causing the injuries or property losses.

To consider the possible danger during the installation or using process of swing gate operator,

installation must strictly comply with the construction standard and electrical operating procedure.

Before installation, please make sure that the power voltage being used matches with the supply

voltage of this product. Please check if the leakage protection switch is installed and the grounding

system is correct.

Please check if additional equipment or materials are required to meet the specific requirements.

The disposal of packaging material must be complying with the local regulation.

Please do not change any parts except for those defined under this manual. Any undefined changes

may cause the malfunction. Any damages to the product arising therefrom shall be beyond the liability

of the company.

Please do not leak water or any liquid into the controller or any other open devices. Please disconnect

the power immediately if any mentioned cases happened.

Please keep this product away from heat and open fire. Or it may damage the components; cause the

failure or other hazards.

Please make sure there is no vehicles

passengers and objects passing through while the swing gate is

moving.

Anti-clip equipment like infrared protection switch must be installed to avoid injuries to person and

property losses. The company shall not be liable for any damage or accident arising therefrom.

The installation

using and maintenance of this product must be carried out by professionals.

Children are not allowed be touch the control devices or remote transmitters.

A warning sign must be placed somewhere on the swing gate according to the national standard.

Please keep this instruction properly for future reference.

Содержание SW300DC

Страница 1: ...SW300DC Swing Gate Opener User Manual ...

Страница 2: ...y Installation 7 8 3 Dimension of Control Box 10 9 Wiring and Debugging 11 9 1 Wiring Instructions 11 9 2 Control Board Drawing and Instructions 12 9 3 Digital Screen Setting 13 9 4 Travel Setting 13 9 5 Trimmer Setting 14 9 6 Learning Remote Control Delete Remote Control 14 9 6 1 Learning Remote Control 14 9 6 2 Delete Remote Control 14 9 6 3 Special Remote Control Key button 15 9 7 Control Board...

Страница 3: ...rements The disposal of packaging material must be complying with the local regulation Please do not change any parts except for those defined under this manual Any undefined changes may cause the malfunction Any damages to the product arising therefrom shall be beyond the liability of the company Please do not leak water or any liquid into the controller or any other open devices Please disconnec...

Страница 4: ...tity 1 Main machine 2 2 Control box 1 3 Manual release key 2 4 Remote control 2 5 Wall bracket 4 6 Front mounting bracket 2 7 Connecting bracket 2 8 Screw M8X25 4 9 Mounting screw short 2 10 Screw M8 45 2 11 Self locking Nut M8 8 12 Limit stopper 1 ...

Страница 5: ...re the these installation accessories according to actual site situation 3 Technical Parameters Model SW300DC Power supply 220V 50Hz 110V 60Hz Motor power 50W Gate moving speed 18 22s 90 Max single leaf weight 300kg Max single leaf length 2 5M Max force 2600N Max piston stroke 32cm Remote control distance 30m Remote control mode Single Four button mode Storage battery optional DC24V 4 5Ah or 9Ah N...

Страница 6: ...e mode adopts planetary transmission to combine with the screw rod transmission This gate opener must be installed inside the enclosure or yard for protection 5 Tools Needed for Standard Installation No 6 Allen Wrench Spirit Level Slotted Screwdriver Tape Phillips Screwdriver Adjustable Wrench X 2 Hatching Pen Note the cables must be suitable for outdoor use ...

Страница 7: ...f infrared sensor 2 0 5mm 10m 4 Cable of alarm lamp 2 0 5mm 10m 5 Cable of electric lock 2 0 5mm 10m 6 Extension cable of storage battery 2 1 5mm 10m 7 Cable of solar power 2 1 5mm 10m Due to different installation environments installer need to prepare power cables for control box and for gate openers Note cable outlet should be downward to prevent rainwater from entering wire along the cable ...

Страница 8: ... Gate Opens Inwards Figure 2 7 2 Gate Opens Outwards Figure 3 A B 100mm 120 mm 140 mm 160 mm 180 mm 200 mm 100mm 102 101 99 98 97 97 120mm 111 108 106 104 103 99 140mm 118 115 112 102 93 96 160mm 117 107 98 91 180mm 103 96 90 200mm 94 ...

Страница 9: ...d 300 800mm above the ground and make sure there are reliable fixed points for mounting brackets 8 1 1 Cable Bury In order to ensure the normal operation of the gate opener and protect the cable from damage please use two PVC pipes to bury the motor and power cables and the control cables separately One PVC pipe for motor and power cables the other one for control cables 8 1 2 Mounting Brackets Fi...

Страница 10: ...the installation please unlock the two main machines Unlock method Open the manual release cover insert the manual release key rotate the key until it s released as shown in Figure 6 then turn the telescopic arm you ll find it s stretched by hand easily Figure 6 D Connect the main machine with connecting brackets by screw and nut as shown in Figure 7 ...

Страница 11: ...n in figure 8 below connect wall bracket with wall according to marked position Then connect main machine with wall bracket by screw and nut Please use spirit level to make sure the installation levelness Figure 8 Figure 9 ...

Страница 12: ...ion as shown in figure 2 Before installing the main machine please make sure the main machine and components are in good mechanical performance and the gate can be manually operated flexibly One control unit can optionally drive one main machine or two main machines Earth leakage circuit breaker must be installed on where the gate movement can be seen and the minimum mounting height for the contro...

Страница 13: ...USE 10A 10A 24V 24V battery battery input input 24V 24V battery battery input input Solar Solar power power input input Solar Solar power power input input Motor2 Motor2 Electric Electric Lock Lock Alarm Alarm Lamp Lamp 24V 24V 12V 12V Motor1 Motor1 Limit Limit signal signal Common Common Motor1 Motor1 Limit Limit power power supply supply Motor2 Motor2 Limit Limit power power supply supply Motor2...

Страница 14: ... 4 FORCE Resistance Force 5 SLOW DOWN Slow Stop Distance 6 SPEED Moving Speed 7 MOTOR1 Motor1 Output 8 MOTOR2 Motor2 Output 9 ELOCK Electric Lock Output 10 BLK Alarm Lamp Output Note pay attention to the negative and positive 11 24V 24V Output Positive 12 12V 12V Output Positive No output under dormant state 13 EM1 Motor1 Hall Sensor Power Output 14 LM1 Motor1 Hall Sensor Limit Signal Input 15 EM2...

Страница 15: ...il the digital screen shows SU After this step the gate will firstly run towards the closing direction and stop and then the gate will automatically open When the two swing gates are fully open the gates will automatically close for the second time and the travel setting will be completed when the gates are closed If the distance of starting slow speed of gate is not appropriate adjust the SLOW DO...

Страница 16: ... travel setting Figure 13 9 6 Learning Remote Control Delete Remote Control 9 6 1 Learning Remote Control Press and hold button the alarm light will keep flashing and digital screen displays remote control mode PO two swing gates single channel mode Pd single gate four channel mode Press the button of the remote control to be learned the digital screen will show the number of current learned remot...

Страница 17: ... select other functions of this menu by and buttons Press SET to confirm or to enter into sub menu To exit menu press PROG If no command for one minute the menu will automatically exit Base Menu Automatic closing mode Standard mode Open Close Stop Dual gates mode To switch single gate mode dual gates mode Single gate mode Community mode Open gate time interval 3 seconds default 15 seconds default ...

Страница 18: ...16 Remote control mode Dual gates single channel mode Four channel mode Single gate single channel mode Delete remote control ...

Страница 19: ...on When the gate opens any gate command will not be responded until it closes automatically If user sends gate command during the closing process then the gate will reopen If a gate command is sent during the automatic closing waiting time this waiting time will be recalculated If the gate is not closed completely for more than three consecutive times the automatic closing function will be cancele...

Страница 20: ...l shorter than 2 seconds then the electric lock cannot be used 3 seconds Automatic Closing Time Automatic closing time can be set as 15 default 30 60 90 seconds 15 seconds Remote Control Mode Dual gates single channel mode Four channel mode Single gate single channel mode Delete all paired remote controls ...

Страница 21: ...exit If no command for one minute the menu will automatically exit Advanced Menu Photo sensor Photo sensor normally on Initial screen Photo sensor normally off Electric lock normally on Alarm lamp Electric lock Alarm lamp normally flash Low consumption mode off Low consumption mode Alarm lamp normally on Low consumption mode on Time of of gate 1 Time of of gate 2 Travel time adjustment Electric lo...

Страница 22: ...20 Gate opener secection Stop block Hall sensor Default setting cancellation Factory default setting Limit switch mode Factory default setting SW400DC SW300DC SW200DC ...

Страница 23: ...sor normally is on Default N O photo sensor normally off N O photo sensor normally on Electric Lock Electric lock normally is on Default Electric lock normally is off Electric lock normally on Alarm Lamp Alarm lamp normally is on 24V power supply Default Alarm lamp normally flashes 24V power supply Alarm lamp normally is on 24V power supply Low Consumption Mode Low consumption mode on The control ...

Страница 24: ...it Switch Mode Stop block Default Hall sensor Stop block Gate Opener Secection SW400DC SW300DC Default SW200DC SW300DC Factory Default Setting Cancel factory default setting Factory default setting completes ...

Страница 25: ...re that the 5 and 6 5 and 7 short circuit if connect infrared sensor please make sure the wiring is correct and the photocell is N C 2 Make sure that the photocell mounting position can be mutually aligned 3 Remove the obstacle 4 Reduce the sensitivity of obstacle Remote control doesn t work 1 Battery level of the remote control is low 2 Remote control learning is not completed 1 Change the remote...

Страница 26: ...ar after the date of invoice 3 Without unauthorized dismantling any product broken or damage due to quality problem we ll offer the repair service for free or replace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty Maintenance Record Check Date Check Content Maintained by ...