VAX-1100
For a measuring range from 10 to 100 V, the instrument must be connected
like that:
These illustrations display display how the VAX1100 must be connected for
a measuring range from 10 to 100 V.
Please note that the jumper must be
pinned on position 2W .
If the instrument is integrated in the circuit like in the left illustration, it is
possible to measure DC current circuits and the discharge of batteries.
If the instrument is integrated in the circuit like in the right illustration, you
can measure the charge process of batteries.
For a measuring range from 0 to 100 V, the instrument must be connected
like that:
These illustrations display display how the VAX1100 must be connected for
a measuring range from 0 to 100 V.
Please note that the jumper must be
pinned on position 3W. Moreover, the measuring modulemust be sup-
plied with a 10 to 30 V DC volatge.
If the instrument is integrated in the circuit like in the left illustration, it is
possible to measure DC current circuits and the discharge of batteries.
If the instrument is integrated in the circuit like in the right illustration, you
can measure the charge process of batteries.
power
source
power
source
load
load
battery
battery
charger
charger