JOWA Ag-S
Silver Ion Water Treatment System
Standard
23/32
6.0
Trouble Shooting
Section 5.5 lists the possible errors that the system will detect. Below is a chart that
can be helpful if the error description does not indicate the issue directly. See section
5.5 for additional details on how to handle errors.
Problem
Cause
Correction
Green Power (LED) not
illuminated or flashing
No power to the Ag-S.
A fuse is defective
Check the power
Replace fuses
Red Alarm (LED) is
illuminated or flashing
Error 0 is shown
If display is blank press
the On/Off button to
show the error screen
Flow has not been detected
in the Chamber
Flow switch out of
adjustment
Defective flow switch
Check the water flow in the
chamber. Flow regulator
should be set for 3 l/min.
Check the adjustment. (see
Section 11, PN 9801010)
Replace flow switch if
defective
Red Alarm (LED) is
illuminated or flashing
Error 1 is shown
If display is blank press
the On/Off button to
show the error screen
Contamination between the
electrode plates
Electrodes were damaged
Wires to electrodes shorted
Run Flush under the Setup
menu at higher than normal
flow rate
Check the electrodes in the
chamber and remove debris
Replace electrode in the
chamber.
Replace wires to electrode
Red Alarm (LED) is
illuminated or flashing
Error 2 is shown
If display is blank press
the On/Off button to
show the error screen
The silver electrode is
used up.
The conductivity of the
water is too low.
The wires to the electrode
are not connected.
Replace silver electrode.
Use a filter to add minerals
to the water.
Properly connect the wires
to the electrode