Quick Start Up Guide
Jetronix-Eco
4
Jovy Systems® Limited
Temperature Unit, to set temperature reading display
in °C or °F.
Keypad Tone, On to activate audible sound with each
press at any key pad button. OFF to deactivate the
audible sound.
TC1 is the default Main Thermocouple reading – Built
in machine thermocouple, to choose the optional
thermocouple as main TC, choose TC2
2-
Process Profile Parameters
a.
Create process Profile
From Main Menu choose Profiler and press Enter.
Then, create a profile
Jetronix-Eco Process Profile divided into optional 1 to
4 stages; user can create a process profile of at least
1 stage. Preheat stage is preprogramed and heaters
power predefined, while the other user define the
hearts power for each zone.
The required inputs for pre heat stage is the stage
ends temperature and dwell time needed at this
temperature
The rest of stages the process profile parameter
includes more inputs for each heating zone power
setting. In the main tab use the Right and Left
buttons for stages parameter inputs or to review the
stage parameters.
To set a stage’s parameter press Up or Down button to the
parameter location change the input value (increase) by press Right
button (decrease) by press Left button.