Jøtul Scan 45i TSI Скачать руководство пользователя страница 27

27

139472_Rev_B   8.28.12

37

Scan

 45

i TSI Replacement Parts

ONLY USE 

REPLACEMENT PARTS 

PROVIDED BY AN 

AUTHORIZED  

SCAN DEALER.

Figure 39.  Burner, Spud and Draw Collar Assemblies

No.  Part Number  Description

223973 

Ribbon Burner

2-32  157266 

Spud Assembly, Complete - GI 

450 

DV II TruStart

129472 

Orifice, Pilot - #51 (NG, Pop-Top)

 

222057 

Orifice, Pilot - #35 (LP)

222925 

Proflame Pilot, NG

117917 

Screw, HWH SMA 8 x 1/2 SL Blk Oxide

22395292 

Spud Cover Plate,  Matte Black 

129669 

Gasket, Spud Plate Assembly

223244 

Bracket, IPI Ignition Board

222924 

Proflame IPI Ignition Board

117922 

Nut, Hex M4 DIN 934 PLAIN

10 

129154 

Terminal Block, 2 Pole 77 series

11 

117912 

Screw, Pan Hd Ph M4 x 12 Blk Ox

12 

224492 

Bracket, Extension Faceplate, GI450 DVII - TSI

13 

224498 

Faceplate, SScreened - TSI

14 

224496 

Switch, Rocker, DPST, Black, Plain

15 

224490 

Switch, Rocker, DPDT, Black, Plain

16 

224495 

Indicator Light, 120V Amber, Neon

17 

222292 

Elbow, 90°, Brass 3/8 NTP X 3/8” Dia Tube

18 

118214 

Screw, #8 X 1/4”, Taptite, SLHWH, SZPL

19 

157412 

Proflame Valve, Manual Hi/Lo, 

20 

129707 

Flex tube w/connectors (3/8” O.D. x 24”)

21 

223953 

Valve Bracket

22 

22410792 

Heat Shield, Battery Box

23 

117975 

Wing Nut, M6 Zinc

24 

22426292 

Battery Holder w/ cover - 4 AA

25 

223901 

Heat Shield, Valve

26 

222280 

Gasket, Drop In Orifice Holder

27 

223231 

Orifice Holder, Drop In Assembly, 12.5 in. tube

28 

220641 

Orifice, #33 - NG

 

045025 

Orifice, #52 - LP

29 

118029 

Washer, Fender .250 x 1.500 dia.

30 

221107 

Gasket, Primary Air Shutter

31 

224104 

Handle, Air Shutter, Internal, GI 450 DVII

32 

221390 

Primary Air Shutter Assembly

33 

224347 

Spark Electrode & Cable,  Proflame Pilot

34 

224348 

Sensing Electrode & Cable,  Proflame Pilot

35 

224349 

Pilot Hood, 2 Flames, Proflame Pilot

36 

129670 

Gasket, Pilot Asy

37 

157264 

Wire Harness, SIT Proflame DFC

38 

129730 

Regulator Knob Extension 

39 

157436 

Draw Collar Band Heater Assembly

40  224886  

TSI AC Snapstat (NC)

41 

224887 

TSI Control Snapstat (NO)

42 

157437 

TSI Wire Harness

43 

224478  

Snapstat Bracket

44 

224730 

Draw Collar Cover

45 

117981 

Strain Relief, Steel

46 

118257 

Hook & Loop Tape, - 2”, self-adhesive

47 

117999 

Screw, #8 x 3/8” SMS Blk Oxide

48 

225345 

Pilot Spacer, 1/2”

49 

220546 

Pilot Spacer, .31”

50 

118218 

Screw, #8 x 1.50” SMS

51*  22397892 

Burner Media Retainer Tray

52*  22417492 

Inner Retainers (2)

53*  223977 

Burner Support

* not illustrated

No.  Part Number  Description

Содержание Scan 45i TSI

Страница 1: ...aucum interrupteur Ne pas vous servir des t l phones se trou vant dans le b timent o vous trouvez Appelez imm diatement votre fournis seur de gaz depuis un voisin Suivez les instructions du fournisseu...

Страница 2: ...d Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructions must remain with the appliance or equipment at the completion of the installat...

Страница 3: ...Starfire Glass Embers or Tumbled Stone burner media is packaged separately from the insert firebox Figure 1 Pull each Trunk Latch down to disengage it from the Glass Frame Glass Frame Latch Locations...

Страница 4: ...s fireplace in sert has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21 88 2009 CSA 2 33 2009 CAN CGA 2 17 M91 and CSA P 4 01 2 for Canada Starfire Glass Ember Kit...

Страница 5: ...the codes have been established in CAN CGA B149 Fuel Installation Code Installer l appareil selon les codes ou reglements locaux ou en l absence de tels reglements selon les Codes d installation CAN...

Страница 6: ...burns or clothing ignition Enfants et adultes doivent tre avertis des dangers des temp ratures de surface lev es et devraient rester l cart pour viter les br lures ou l inflammation des v tements Youn...

Страница 7: ...ials Figure 2 Firebox dimensions Leg Leveling Bracket Note Two right and left brackets are factory installed The brackets allow the insert to be raised up to 2 1 2 off of the hearth Also note that use...

Страница 8: ...imum 18 forward of the firebox glass panel Raised Hearth A raised hearth that is at least 6 high requires a non combustible hearth that extends a minimum 12 from the fireplace glass and and is a minim...

Страница 9: ...Figure 5 Baseline Mantel and Trim clearance requirements The insert is raised 2 on the leveling brackets Leg Leveler Bolts and Brackets This feature enables greater installation flexibility beyond el...

Страница 10: ...3 M99 TEST METHODS AND RESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Vent Guidelines All vent compo...

Страница 11: ...ct to the insert 9 Compress the ducts so that they are hanging above the height of the fireplace opening and are out of the way 10 Position the insert without surround panels half way inside the firep...

Страница 12: ...ESULTING ITS WHI PRODUCT CERTIFICATION THE CODE AUTHORITY HAVING JURISDICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLATION METHOD Figure 9 Venting through prefabricated fireplace chimn...

Страница 13: ...is still required to allow fresh air into the chimney flue and ultimately into the intake flex and insert D Attach the Fireplace Conversion Notice to the back of the fireplace if appropriate 9 Surrou...

Страница 14: ...ARY MANIFOLD PRESSURES inches water column MIN MAX NATURAL GAS 1 6 WC 3 5 WC PROPANE 5 3 WC 11 0 WC ALWAYS TEST PRESSURE WITH THE VALVE REGULATOR ADJUSTED TO THE HIGHEST SETTING Figure 11 Gas connecti...

Страница 15: ...ilot rectification and or frequent burner outages Little variation in flame picture between HI and LO regulator settings Insufficient gas to support more than one ap pliance causing nuisance outages o...

Страница 16: ...TABLIS DANS LES IN STRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L EQUIPEMENT Conversion Kit LP 157249 NG 157250 Tools required 1 2 13 mm open end wrench or deep well socket Torx T20 driver 1 4 nut dr...

Страница 17: ...ould not be able to move to the right or left 10 Replace the variable regulator on the gas control valve Remove the TruStart switch faceplate and move the assembly out of the way to access the regulat...

Страница 18: ...aller and applied to the appli ance at the time of the conversion See fig 19 Derating procedure 1 Turn off gas supply to the appliance and disconnect from electrical power source 2 Remove the Glass Fr...

Страница 19: ...ing the air shutter will generate a flame that is blue and transparent or an anemic flame This flame is generally more efficient but not very attractive We recommend the following settings for the Sca...

Страница 20: ...shutter See figs 14 and 15 pages 16 17 4 Use a 10 mm socket to remove the left and right burner bracket nuts Remove the Burner Bracket from the firebox See fig 23 5 Bend the two upper rear tabs down...

Страница 21: ...ure 26 Install Glass Embers Tumbled Stones Kit 157245 NOTE Install the optional Reflective Glass Panels before installing the stones Spread the stones evenly around the burner media tray CAUTION Take...

Страница 22: ...mote Control connections GREEN GRAY The optional J tul Remote Control can be used with the Scan 45i TSI however the receiver must be installed outside of the firebox cabinet If there is no room for it...

Страница 23: ...mable Backing Plate Front Assembly Riser Bar Leveling Brackets Standard Ventilated Control Door Optional Full Panel Control Door NOTE THE OPTIONAL FULL PANEL CONTROL DOOR MAY ONLY BE USED IN CONJUNCTI...

Страница 24: ...r remote calls for heat the PREHEAT lamp will indicate Draw Collar warm up Pilot ignition occurs after approximately two to three minutes or when the vent is sufficiently heated to induce draft follow...

Страница 25: ...dy not lifting or float ing The flame should be blue in color around the pilot hood with traces of yellow toward the outer edges It is important that the pilot flame engulf the top 1 8 of the flame re...

Страница 26: ...ems 22 and 24 fig 39 on page 27 Use four AA batteries noting the polarity indicated on the box Glass Care Moisturecondensationisanormaloccurrencewithgasappli ancesandparticulateaccumulationmayappearon...

Страница 27: ...onnectors 3 8 O D x 24 21 223953 Valve Bracket 22 22410792 Heat Shield Battery Box 23 117975 Wing Nut M6 Zinc 24 22426292 Battery Holder w cover 4 AA 25 223901 Heat Shield Valve 26 222280 Gasket Drop...

Страница 28: ...0 F No Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 SL Blk Oxide 2 222799 Blower Bracket 3 222072 Blower TransFlow 12 Cage 120 CFM No Part Number Description 1 117917 Screw HWH SMA 8 x 1 2 S...

Страница 29: ...H WH M 1 3 2 4 5 6 7 8 9 10 GY GN GN BK BK BK TAN TAN BK WH BK WH BL GN BK BK BK RD BK RD BK RD BK GN YL GN BK YL GN GN OR GN TAN 13 12 TAN WH 11 14 BK BK BK WH BK TAN TAN TAN TAN NOTE Circled numbers...

Страница 30: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 31: ...Never use tools If the knob will not turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any pa...

Страница 32: ...lation it is important that these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in specification color or typ...

Отзывы: