Jøtul I 500 FL Скачать руководство пользователя страница 2

14

ENGLISH

Table of contents

Installation manual with technical data

1.0   Regulatory information ................................14

2.0   Technical data  ...............................................14

3.0   Installation  ...................................................15

4.0   Servicing ........................................................ 17

5.0   Optional Equipment ..................................... 17

Figures .................................................................. 38

General use and maintenance manual

6.0  

Safety 

precautions

7.0   Choice of fuel

8.0  

Use

9.0  

Maintenance

10.0   Operational problems - troubleshooting

On all our products there is a label 
indicating the serial number and 
year. Write this number in the 
place indicated in the installation 
instructions. 

Always quote this serial number when 
contacting your retailer or Jøtul.

les combustibles recommandés.

Respectez les consignes d'utilisation. Utilisez uniquement

Verwenden Sie nur empfohlenen Brennstoffen.

Montage- und Bedienungsanleitung beachten. 

Follow user`s instructions. Use only recommended fuels.

standard

Certificate/

The appliance can be used in a shared flue.

Minimum distance to adjacent combustible materials:

Emission of CO in combustion products

Serial no: Y-xxxx, Year: 200x

Manufacturer:

N-1602 Fredrikstad
Norway

Jøtul AS
POB 1441

Sweden

EUR

Intermittent

Nominal heat output      

Norway

Country

Operational type

Fuel type

Operation range

Efficiency

Klasse II

Classification

Standard

Flue gas temperature             

Room heater fired by solid fuel

Product:

Jøtul

SP Sveriges Provnings- och

221546

Forskningsinstitut AB
SP Swedish National 
Testing and Research
Institute

:

Approved by

:

:

:
:

:
:

:

Minimum distance to adjacent combustible materials:

OGC 

SP 

EN 

Serial no.

1.0 Regulatory information

Installation of a fireplace must be according to local codes and 
regulations in each country.

All local regulations, including thosethat refer to national and 
European standards, shall be complied with when installing the 
product.

Both an installation manual with technical data and a general 
user and maintenance manual accompany the product. The 
installation can only be taken into use after it has been checked 
by a qualified inspector.

An approval label made of heat resistant material is located on the 
heat shield at the back of the product. This contains information 
about identification and documentation for the product.

2.0 Technical data

Material: Cast 

iron

Finish: Black 

paint

Fuel: Wood
Log length, max.: 

40 cm

Flue outlet: 

Top 

Flue dimension 
(outside the outlet) :  

150 mm/177 cm

2

 cross section 

Approx. weight: 

132 kg

Optional extras: 

Panels, glass ash lip and ash  

 solution 
Dimensions, distances etc.:  See 

fig.1

Technical data according to EN 13229

Nominal heat output: 

9,0 kW

Smoke gas mass flow: 

8,1 g/s

Recommended chimney draught:  12 Pa
Effiency: 80%@9,9 

kW

CO emission (13% O

2

): 0,06 

%

Flue gas temperature: 

314

0  

C

Operating mode:  

Intermittent

“Intermittent combustion” here means normal use of a stove. 
That is to say, if you want to continue producing heat, you add 
more fuel as soon as the previous load of wood has burnt down 
to embers.

Wood consumption

The efficiency of Jøtul I 

500 

Series gives it a nominal heat output of 

9.0 kW

. Wood consumption, at nominal heat output: Approx. 

2.8 

kg/h. 

The size of the pieces of wood should be:

 

Kindling (finely split wood):

Length: approx. 35 - 40 cm
Diameter: 3 - 5 cm
Quantity required each time: 8 - 10 pieces

Wood (split wood):

Recommended length: 35 cm
Diameter:  Approx. 8 - 12 cm
Interval for adding wood: Approx. every 50 minutes
Fire size: 2,3 kg (nominal output)
Quantity required each time:  4 pieces

Nominal heat output is achieved when the air vent is open 
approx. 75 % (fig. 4 A).