14
ENGLISH
Table of contents
Installation manual with technical data
1.0 Regulatory information ................................14
2.0 Technical data ...............................................14
3.0 Installation ...................................................15
4.0 Servicing ........................................................ 17
5.0 Optional Equipment ..................................... 17
Figures .................................................................. 38
General use and maintenance manual
6.0
Safety
precautions
7.0 Choice of fuel
8.0
Use
9.0
Maintenance
10.0 Operational problems - troubleshooting
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number when
contacting your retailer or Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
1.0 Regulatory information
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including thosethat refer to national and
European standards, shall be complied with when installing the
product.
Both an installation manual with technical data and a general
user and maintenance manual accompany the product. The
installation can only be taken into use after it has been checked
by a qualified inspector.
An approval label made of heat resistant material is located on the
heat shield at the back of the product. This contains information
about identification and documentation for the product.
2.0 Technical data
Material: Cast
iron
Finish: Black
paint
Fuel: Wood
Log length, max.:
40 cm
Flue outlet:
Top
Flue dimension
(outside the outlet) :
150 mm/177 cm
2
cross section
Approx. weight:
132 kg
Optional extras:
Panels, glass ash lip and ash
solution
Dimensions, distances etc.: See
fig.1
Technical data according to EN 13229
Nominal heat output:
9,0 kW
Smoke gas mass flow:
8,1 g/s
Recommended chimney draught: 12 Pa
Effiency: 80%@9,9
kW
CO emission (13% O
2
): 0,06
%
Flue gas temperature:
314
0
C
Operating mode:
Intermittent
“Intermittent combustion” here means normal use of a stove.
That is to say, if you want to continue producing heat, you add
more fuel as soon as the previous load of wood has burnt down
to embers.
Wood consumption
The efficiency of Jøtul I
500
Series gives it a nominal heat output of
9.0 kW
. Wood consumption, at nominal heat output: Approx.
2.8
kg/h.
The size of the pieces of wood should be:
Kindling (finely split wood):
Length: approx. 35 - 40 cm
Diameter: 3 - 5 cm
Quantity required each time: 8 - 10 pieces
Wood (split wood):
Recommended length: 35 cm
Diameter: Approx. 8 - 12 cm
Interval for adding wood: Approx. every 50 minutes
Fire size: 2,3 kg (nominal output)
Quantity required each time: 4 pieces
Nominal heat output is achieved when the air vent is open
approx. 75 % (fig. 4 A).