background image

14

3.0 Installation

3.1  Floor

Foundations

It must be ensured that the foundations are dimensioned for 

the fireplace. Cf. 

«2.0 Technical data»

 for specification of weight. 

It is recommended that flooring which is not fastened to the 

foundations – so-called floating flooring – is removed during 

installation.  

Requirements  for  protection  of  wooden 

flooring 

Jøtul F 

602

 has a heat shield underneath which protects the floor 

from radiation. The product can therefore be placed directly on a 

wooden floor that is covered by a metal plate or other suitable, 

non-inflammable  material. The  recommended  minimum 

thickness is 0,9 mm. 

Any flooring made of combustible material, such as linoleum, 

carpets, etc. must be removed from under the floor plate.

Requirement  for  protecting  combustible 

flooring  in  front  of  fireplace

The front plate must be in accordance with national laws and 

regulations.

Contact your local building authorities regarding restrictions and 

installation requirements.

3.2 Walls

Distance  from  the  wall  of  flammable 

material  –  cf.  fig.  1   

The fireplace is authorised for use with an uninsulated flue 

with the distances to the wall of flammable material as shown 

in 

fig 1. 

Distance  to  the  flammable  wall  protected  by 

a  firewall

Firewall requirement

The firewall must be at least 

100 mm thick 

 and be made of brick, 

concrete-stone or light concrete. Other materials and structures 

with satisfactory documentation may also be used.

3.3  Ceiling

Jøtul F 

602

 may be assembled with the upper edge of the hot 

air aperture min 

1200 mm

 beneath the ceiling of the flammable 

material.

3.4  Chimneys  and  flue  pipes

•  A chimney can be linked to the fireplace and flue approved 

for solid fuel-fired fireplaces with a flue gas temperature as 

specified in 

«2.0 Technical data»

•  The cross-section of the chimney must be at least equal to 

the cross-section of the flue. Please use 

«2.0 Technical data» 

to calculate the correct cross-section of the chimney. 

•  Several  solid  fuel-fired  fireplaces  can  be  connected  to 

the same chimney if the cross-section of the chimney is 

adequate.

•  Connection to the chimney must be carried out in accordance 

with the installation instructions from the supplier of the 

chimney. 

•  Before making a hole in the chimney the fireplace should be 

test-mounted in order to correctly mark the position of the 

fireplace and the hole in the chimney.  See 

fig. 1

 for minimum 

dimensions. 

•  Ensure that the flue pipe is inclined all the way up to the 

chimney.

•  Use a flue pipe bend with a sweeping hatch that allows it 

to be swept.

Be aware of the fact that connections must have a certain 

flexibility in order to prevent movement in the installation 

leading to cracks.

 N.B. A correct and sealed connection is very 

important for the proper functioning of the product.
The chimney draught, see «2.0 Technical data». If the draught is 

too strong you can install and operate a flue damper to control 

the draught.

3.5  Assembling  the  stove

N.B. Check that the fireplace is free of any damage prior to 

commencing installation. 

The product is heavy! Make sure you have assistance when 

erecting and installing the fireplace.

The product is delivered in a single packing case where the heat 

shield and door knob must be assembled.

1.  Remove the cooking plate and all the separate parts inside 

the stove. 

(Fig. 2)

2.  If it is necessary to protect the walls, use the enclosed heat 

shield. Use the bracket to connect the side heat shield to the 

base heat shield. Fasten the bracket in the center of the base 

plate with a screw. 

(Fig. 3)

3.  Guide the flaps on the top of the side heat shield into the 

groove under the top plate.

4.  The flue outlet 

(fig. 4A)

 and the blanking plate 

(fig. 4B)

 

exchange positions if the smoke outlet on top of the stove 

is preferred. The  two screws on  the flue outlet may be 

somewhat difficult to release. Hold on to the nut on the inside 

with a small wrench of the flue outlet to release the screws 

on the outside. Ensure all possible unused flue outlets are 

suitably blanked off.

5.  Place the flue pipe’s end outside the product’s smoke outlet. 

Fill any gaps between the flue pipe and smoke outlet with 

suitable gasket.

6.  Connect the knob 

(fig. 5C)

 to the door latch with the screw 

and nut provided.

7.  Place the stove into its final position and guide the flue pipe 

onto the stove’s chimney collar and attach it.

8.  Follow the installation instructions given by the supplier of 

the chimney. 

eNgliSh

For more information on Jøtul visit www.barbourproductsearch.info