11
ENGLISH
Fig. 11 Mounting of external air supply connection
1
2
1. Place the external air supply connection on the outside of
the external air supply adaptor.This works the same way
for both wall and
fl
oor outlet.
2. Tighten with screwdriver.
4.4 Location of approval label
Fig. 12 Approval label
A
1. The approval label
(A)
is located on the bottom of the
stove.
4.5 Chimney and
fl
ue pipe
• The
fi
replace must only be connected to a chimney and
fl
ue pipe approved for solid fuel
fi
replaces with
fl
ue gas
temperatures as speci
fi
ed in «
2.0 Technical Data
».
• For
fl
ue pipe dimension see “
2.0 Technical Data
”. NB:
The chimney’s diameter must be at least just as big as the
fl
ue pipe.
• Connection to the chimney must be carried out in
accordance with the chimney supplier’s installation
instructions.
• Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the
fi
replace and the hole in the chimney. See
fi
g. 1 for
minimum dimensions.
• Use
a
fl
ue pipe bend with a sweep hatch to allow sweeping.
• Please note that it is extremely important for connections
to have a degree of
fl
exibility. This is to prevent any
movement in the installation leading to the formation of
cracks.
• For recommended chimney draught, see «
2.0 Technical
Data
».
NB!
The minimum recommended chimney length is 3.5 m
from the
fl
ue pipe insert. If the draught is too strong, a
fl
ue
pipe damper can be installed and used to reduce the draugh
If a
fl
ue damper is
fi
tted it shall be of a type, which does not
block the
fl
ue totally. The damper shall be easy to operate and
incorporate an aperture within the blade, which in a continuous
area occupies at least 20 cm2 or 3 % of the cross-sectional
area of the blade if this is greater.
The position of the damper shall be recognizable from the
setting of the device.
If a draught regulator is
fi
tted the minimum cross sectional
area requirement shall not be applicable but the device shall
be easily accessible for cleaning.
Assembly of
fl
ue pipe
The product is assembled for a top outlet as standard.
Fig. 13 Assembling the
fl
ue pipe
1
2
1. Pull o
ff
the protective paper from the supplied gasket
and attach it to the outside of the
fl
ue pipe
2. Insert the
fl
ue pipe into the smoke outlet.
Flue pipe is installed in the same way for top and rear outlet.