5
Table of contents
Installation manual with technical data
1.0 Relationship to the authorities ............................ 5
2.0 Technical data .................................................... 5
3.0 Safety ................................................................. 6
4.0 Installation ......................................................... 12
5.0 Daily use ............................................................. 21
6.0 Maintenance ....................................................... 22
7.0 Service................................................................ 22
9.0 Optional Equipment ........................................... 24
10. Troubleshooting .................................................. 24
10.0 Recycling .......................................................... 25
11 Guaranee terms ................................................... 25
1.0 Relationship to the
authorities
Installation of a fi replace must be according to local codes
and regulations in each country. All local regulations, including
those which refer to national and European standards, must
be observed when installing the product.
The installation can only be put into use after it has been
checked by a qualifi ed inspector. Contact your local building
authorities before installing a new fi replace.
A product approval plate of heat-resistant material is to be
found at the back of the base / on the inside of the front cover
of the pedestal. This contains information about identifi cation
and documentation for the product.
2.0 Technical data
Material:
Cast iron / steel
Finish:
Black paint
Flue outlet:
Top, rear
Flue pipe dimension:
Ø150 mm
Outside air connection:
Alu. fl ex. - Ø100 mm
Approx. weight:
Burnchamber with pedestal:
120 kg
Burnchamber with base:
140 kg
Optional eqeuipment:
Ø 100 external air supply
Dimensions, distances:
See
fi g. 1
Technical data in acc. with EN 13240 and NS 3058 / 3059
Nominal heat output:
4,7 kW
Flue gas volume:
3,7 g/s
Chimney draught, EN 13240:
12 Pa
Recommended negative pressure
in smoke outlet:
16 Pa
Effi ciency:
83%@5,4 kW
CO emissions (13% O2):
0,10
%
CO emissions (13% O2):
1180 mg / Nm3
NOx at 13% O2:
148 mg / Nm
3
OGC @ 13 % O2:
79 mg /Nm3
Particle emission NS 3058 / 3059: 1,89 g / kg
Air consumption:
3,1 liter/sek.
Chimney temperature, EN 13240: 260
0
C
Dust:
5
mg/Nm3@13%O2
Type of fuel:
Wood
Max. log length:
20 cm
Fuel consumption:
1,52 kg/h
Max. kindling amount:
1,54 kg
Nominal kindling amount:
1,25 kg
Operation:
Intermittent
Intermittent combustion in this context means normal use
of the fi replace, i.e. fuel is added as soon as the fuel has
burnt down to a suitable amount of embers.
ENGLISH
UK - Register your fi replace at jotul.
com for a 25-year warranty.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number when