16
3 PRIMARY BATTERY
3 . 1
H O W T O C H A N G E T H E B A T T E R Y
The primary battery unit is a 7.2V / 5000mAh lithium cell.This unit is specially
designed for GMDSS emergency use to preserve a long shelf- and operating-life.
Type no. of battery: X-93002
Battery change procedure:
1)
Hold down the two push-buttons on each side, and pull the battery pack
out of the housing.
2)
Check the gasket inside the housing for no damage.
If it is broken, replace it with a new (stock no. X-93024). Remove dirt when
replacing the gasket.
3)
Replace the expired battery.The label on the battery is marked with date
of replacement.
The primary battery is equipped with a seal to prevent inadvertent use.
Break this seal before use. Breaking this seal indicates that the shelf life has
expired.
4)
Push the new battery unit into the housing until you hear the two push-
buttons are clicking into right position.Tron VHF will not be waterproof
unless the pushbuttons are in correct position.
3 . 2
W H E N T O C H A N G E T H E B A T T E R Y
Replace the battery before expiry date.The battery pack, 93002, has a shelf life
of 4 years.
If TronVHF is indicating low voltage during a regular test procedure, also change the
battery.The Tx LED also flashes when battery voltage is low.
To prevent the possibility of being in an emergency situation with a TronVHF
equipped with a used battery, we strongly recommend storing an extra battery-set,
93002, in lifeboats and rafts. Store this battery without breaking the plastic bag
sealing.
Содержание Tron VHF
Страница 1: ...Tron VHF your safety our concern GB OPERATORS MANUAL www los grafisk no O nr 250854...
Страница 3: ...3 CHANGES RECORD NO CHAPTER VERSION NEW MANUAL EM3903 CAP 5 B REVISION HISTORY...
Страница 8: ...8...
Страница 9: ...9 DATE N T B SIGN INSP N NEW EPIRB INSTALLED T TEST B NEW BATTERY TEST AND MAINTENANCE RECORD...
Страница 31: ......