jotron.com
Page 18 of 56
Test sequence
Position indicator
RLS indicator
Test indicator Strobe light
Extended self-
test started
-
-
On
-
Waiting for
position
Triple flashes
-
-
-
Position
achieved
On for 1 second
-
-
-
Self-test
started
-
-
On
-
Signals
transmitted
-
-
Multiple short
off periods
-
RLS enabled *
-
On for 1
second
-
-
Extended self-
test successful
-
-
-
One flash
If one of the above tests are unsuccessful, the remaining test sequences
will not be performed, and the test indicator will indicate self-test failure.
Self-test
failure
Multiple
flashes**
*For EPIRBs with RLS disabled the RLS indicator will remain off.
**See table in section 3.5.3 for on failure indications.