6.1
Con
fi
gura
Ɵ
on group
6.1
Con
fi
gura on group
Menu
Configuration
AM
Sets parameters for AM operation. Power output and
modulation.
Audio
Set parameters for audio in/out, sensitivity, audio
source,tone generator etc.
Single Channel Mode
Set the radio to single channel mode. (Equals value in
Euro control MIB)
Access levels:
SysOp + Technician
Access levels:
SysOp
Figure 16: Con
fi
gura on group
6.1.1
AM
•
Output power
– Range:
30.0 - 40.0 dBm, 0.1 dB step
– Default:
40.0 dBm (10 W)
– Details:
Set the output power. Max. level depends on radio model: 37.0 dBm for TR-910 MP, 40.0
dBm for TR-910 (All others).
•
Modula on %
– Range:
10.0 - 95 %, 1 % step
– Default:
85 %
– Details:
Set the modula on depth for AM opera on. Use default for best performance with regards
to intelligibly and adjacent channel performance.
6.1.2
Audio
•
Input source
– Range:
Auto | Line | Mic | Modgen | VoIP (Availability of certain choices may depend on op ons
enabled)
– Default:
Auto
– Details:
The input source determines from where the audio is applied to the transmi er.
Auto:
Uses line input from any of the audio input sources that keys the radio (Line, Mic. or VoIP
[ED137]).
PTT from microphone:
Mic
46
jotron.com
Doc. No.: 103614 TR-910 Operator Rev. AB
Содержание TR-910
Страница 1: ...TR 910 Multipurpose VHF Airband Radio Operator Installation and Technical Manual...
Страница 29: ...4 4 Installa on of TR 910 Figure 8 TR 910 MP Doc No 103614 TR 910 Operator Rev AB jotron com 29...
Страница 30: ...4 4 Installa on of TR 910 Figure 9 TR 910 MP 30 jotron com Doc No 103614 TR 910 Operator Rev AB...
Страница 31: ...4 4 Installa on of TR 910 Figure 10 TR 910 MP Doc No 103614 TR 910 Operator Rev AB jotron com 31...