RCH-20
5-2
Charge control circuits
Each battery position has a separate switch to select charging. Q3 and Q7 are used to switch charging
on and off, and are controlled by output ports on IC1, to select which battery is going to be charged.
In addition to the voltage and temperature reading, an internal timer is used to terminate the charging
if no other termination occurs within approx 4.5 hours.
When there is no battery, or a fully charge battery is placed in the slot, the charger will send short
charging pulses to each slot. This is used to detect whether a battery is present in each slot, as well as
supplying trickle charge to fully charged batteries. The trickle charge is approx 10mA on average.
Status of the charging is indicated by D1 and D2, which are bicolour LED’s. The function of these
diodes is explained in chapter 4.
Содержание RCH-20
Страница 1: ...RCH 20 JOTRON electronics a s RCH 20 Charger for Tron TR20 GMDSS PLUS Technical Handbook Dec 2001 ...
Страница 12: ...RCH 20 6 1 6 MAINTENANCE No maintenance is necessary ...
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ...RCH 20 8 1 8 PARTS LISTS Part list Complete Charger BOM 99920 Part list Main Board BOM 80011 ...