82694_
Op&Ins MAN_RA2500_D 5-15
5.6.3 Format
BCF:
Configure RA-2500 parameters. See paragraph 10.2.1 section 2.
$--BCF, xxxxxxxxx,x, llll.ll, a, yyyyy.yy, a, x, xxxx, xxxx, xxxx,xxxx,x,x,x,x,cc*hh<CR><LF>
receiver Talker ID
N/A
N/A
N/A
N/A
N/A
N/A
Rx channel B
4
Rx channel A
4
Position accuracy
3
Longitude E/W
2
Latitude N/S
2
Position source
1
N/A
Notes:
1. Identifies the source of the position.
Value 0 = surveyed position
Value 1 = internal source
Value 2 = external source
2. Surveyed position of the base station. The position is only applicable to fixed base stations.
Within the base station, the "electronic position fixing device" parameter is set to a value of
7 indicating a surveyed position. Mobile or non-fixed base stations receive their position
information by another means.
3. 0 = low > 10m.
1 = high < 10m ; differential mode of DGNSS.
4. VHF channel number, see paragraph 9