Joto E-HP-JMP-2S5E Скачать руководство пользователя страница 14

14

www.jotoimagingsupplies.com 1-800-565-5686 Blaine, WA | Las Vegas, NV | Antioch TN | Coquitlam, BC | Brampton, ON

Circuit Diagram

Содержание E-HP-JMP-2S5E

Страница 1: ...Joto Digital Mug Press Manual Dual Station includes 5 Elements Model No E HP JMP 2S5E OPERATOR S MANUAL Dual Station Includes 5 elements This product is SGS Electrical Safety Certified...

Страница 2: ...epair could increase the risk of fire electric shock or injury to persons when the equipment is used If mug press being used by or near children please make sure that it is supervised Do not leave equ...

Страница 3: ...requires written consent from Joto Errors and amendments of technical details excepted all rights reserved Joto is not liable for any direct or indirect damages caused by the use of this product Tabl...

Страница 4: ...x235mm for 6oz 9oz 10oz etc Mug 130x235mm for 11oz 15oz etc Mug 12oz 17oz Latte Mug Voltage 220V 1Phase 110V 1Phase Power 2x 300W 600W 5 5A Recommended Settings 30 280s 356 400 F or 180 200 C Time Ran...

Страница 5: ...5 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Mug Press Overview FRONT VIEW SIDE VIEW TOP VIEW...

Страница 6: ...lies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Machine Parts Diagram Mug Heater Limit Switch Digital Controller Handle Bar Grip Pressure Adjustment Knob Power Switc...

Страница 7: ...in F or C F stands for Fahrenheit C stands for Celsius 2 Once you select Fahrenheit or Celsius press OK to save 3 Use the arrow to change the value of the set temperature The left light in the middle...

Страница 8: ...n Jar 12oz Enamel Cup 14oz 17oz Travel Mug 16oz 20oz Beer Stein Water Bottle Element SKU X HP JMP 02 17oz Coke Shaped Bottle Water Bottle with Bamboo lid 650ml Aluminium Bottle with Straw Stainless St...

Страница 9: ...press Close the mug press Note Ensure the timer starts immediately after closing the press If it does not take the bottle out wait for the temperature to go up to the set temp 6 Timer will start coun...

Страница 10: ...detailed instructions 4 With the Mug Press open unscrew the four screws that hold the mug element in place 5 Gently slide the mug element out of the mug press Please be careful not to damage the cord...

Страница 11: ...ce Mug elements will wear out over time When they wear out you will need to replace them with new ones The rated life expectancy of an mug element is approximately 1000 2000 mugs Elements may wear out...

Страница 12: ...agingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Expanded Diagram 18 19 34 21 15 38 1 6 10 7 16 23 13 14 17 22 19 25 28 29 30 31 33 37 2 8 3 4 5 9 12 20 36 2...

Страница 13: ...witch 2 16 Mug Press Handle Base 2 17 Guide Post 1 2 18 Mug Press Handle 2 19 Mug Press Handle Connector 4 20 Rivet Head 12 21 Mug Press Handle Plate 2 22 Switch Plate 2 23 Mug Element Top Plate 2 Ser...

Страница 14: ...14 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Circuit Diagram...

Страница 15: ...d JOTO will ship the replacement or repaired component freight prepaid by JOTO g This warranty is effective only if the product or component is installed in a location and manner prescribed by JOTO in...

Страница 16: ...www jotoimagingsupplies com Tel 1 800 565 5686 Fax 1 800 565 5622 Coquitlam BC Brampton ON Blaine WA Las Vegas NV Antioch TN...