Safety Instructions

For Use By Qualified Personnel Only 

When using your Heat Press,

basic precautions should always be followed,

including the following:

Read all instructions.

Use heat press only for its intended use.

Always keep the heat press dry.  Do not get the heat press wet to reduce the risk of electric shock.  

Do not store heat press in a wet/ damp area.  

Never pull cord to disconnect the power. Instead, grasp plug and pull to disconnect from power 

outlet.

Make sure you protect the power cord by keeping it away from hot surfaces. Avoid placing objects 

on top of the cord. This could cause damage to the cord and could be a fire hazard risk. 

Do not operate heat press with a damaged cord or if the equipment has been damaged.  To prevent 

risks of injury, please do not disassemble or attempt to repair the heat press by yourself if you are 

not qualify to do so. Instead, call or take it to a qualified service person for examination and repair. 

Incorrect assembly or repair could increase the risk of fire, electric shock, or injury to persons when 

the equipment is used.

If heat press being used by or near children, please make sure that it is supervised. Do not leave 

equipment unattended while connected.

Metal parts on the press can become hot.  Avoid touching the hot metal parts to prevent burns.  

Proceed with caution when using the heat press.

To reduce the likelihood of circuit overload, Joto recommends to use a dedicated circuit if possible.

Make sure that the cord is safely secured so it cannot be pulled or tripped over. 

If you need to use an extension cord, make sure you use a 20 amperage rated cord. Cords rated 

below 20 amperage can overheat. Make sure that the extension cord  is safely secured so it cannot 

be pulled or tripped over. 

 

Note:  This heat press should not be set to exceed 400

˚

F (200

˚

C).  Setting the press tempera

-

ture to above 400

˚

F (200

˚

C) may cause a fire hazard.

PLEASE KEEP THE BOX THAT YOUR HEAT PRESS ARRIVED IN, 

 

ALONG WITH ALL ORIGINAL PACKAGING.

Содержание E-HP-JLF-XSTM-40

Страница 1: ...Joto Pneumatic Large Format Heat Press XSTM 40 XSTM 48 Model No E HP JLF XSTM 40 E HP JLF XSTM 48 OPERATOR S MANUAL...

Страница 2: ...f you are not qualify to do so Instead call or take it to a qualified service person for examination and repair Incorrect assembly or repair could increase the risk of fire electric shock or injury to...

Страница 3: ...ual carefully Reproduction of this manual requires written consent from Joto Errors and amendments of technical details excepted all rights reserved Joto is not liable for any direct or indirect damag...

Страница 4: ...x 100cm Up to 40 x 48 100 x 120cm Controller GY 06 Digital Controller GY 06 Digital Controller Printable Materials Up to 6 96 177mm thickness Up to 6 96 177mm thickness Voltage 380V 3 Phase 380V 3 Ph...

Страница 5: ...65 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Machine Parts Diagram PLC Digital Touch Screen Up and bottom tray Air filter Over wire explosion proof box Left and right borders Gre...

Страница 6: ...lue Current Time 4 Right side SV value Set Press Temperature 5 Left side SV value Set Press Time Setting Press Temperature Press the corresponding number of SV to start Touch the F or C buttons to cho...

Страница 7: ...nsure please refer to the instructions you received with your transfer materials 7 Push the green start up switch The platen will close automatically The current time value will start counting down On...

Страница 8: ...onds Peel Hot to Cold MultiCut Style Temperature 310 330 F Time 15 20 seconds Peel Hot to Cold Transfer Vinyls CL TrimFree Dark REQUIRE A WHITE TONER PRINTER Temperature 310 F 1st Press Time 120 secon...

Страница 9: ...e 120 seconds Peel Immediate Method Substrate face up Image face down iLumipiX Photo Panels Temperature 400 F Time 65 150 seconds Time may varied based on size Scan the QR code on the left for instruc...

Страница 10: ...if heat press is not used for more than 30 minutes The heat releasing fan will automatically starts when the temperature of heat platen reaches 80 degree C 176 degree F It helps to reduce the temperat...

Страница 11: ...11 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Schematic Diagram...

Страница 12: ...12 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Expanded Diagram...

Страница 13: ...electric control box 1 7 Rear rail fixing plate 2 27 Cover plate for heat platen 1 8 Front rail fixing plate 2 28 Fixing bolt 6 9 Solenoid valve 2 29 Upper adapter plate 1 10 Front plate 1 30 Governor...

Страница 14: ...14 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Circuit Diagram...

Страница 15: ...purchaser and JOTO will ship the replacement or repaired component freight prepaid by JOTO g This warranty is effective only if the product or component is installed in a location and manner prescribe...

Страница 16: ...www jotoimagingsupplies com Tel 1 800 565 5686 Fax 1 800 565 5622 Coquitlam BC Brampton ON Blaine WA Las Vegas NV Antioch TN...

Отзывы: