Joto E-HP-JAR-DS-1620 Скачать руководство пользователя страница 2

2

www.jotoimagingsupplies.com 1-800-565-5686 Blaine, WA | Las Vegas, NV | Antioch TN | Coquitlam, BC | Brampton, ON

Safety Instructions

For Use By Qualified Personnel Only 

When using your Heat Press,

basic precautions should always be followed,

including the following:

Read all instructions.

Use heat press only for its intended use.

Always keep the heat press dry.  Do not get the heat press wet to reduce the risk of electric shock.  

Do not store heat press in a wet/ damp area.  

Never pull cord to disconnect the power. Instead, grasp plug and pull to disconnect from power 

outlet.

Make sure you protect the power cord by keeping it away from hot surfaces. Avoid placing objects 

on top of the cord. This could cause damage to the cord and could be a fire hazard risk. 

Do not operate heat press with a damaged cord or if the equipment has been damaged.  To prevent 

risks of injury, please do not disassemble or attempt to repair the heat press by yourself if you are 

not qualify to do so. Instead, call or take it to a qualified service person for examination and repair. 

Incorrect assembly or repair could increase the risk of fire, electric shock, or injury to persons when 

the equipment is used.

If heat press being used by or near children, please make sure that it is supervised. Do not leave 

equipment unattended while connected.

Metal parts on the press can become hot.  Avoid touching the hot metal parts to prevent burns.  

Proceed with caution when using the heat press.

To reduce the likelihood of circuit overload, Joto recommends to use a dedicated circuit if possible.

Make sure that the cord is safely secured so it cannot be pulled or tripped over. 

If you need to use an extension cord, make sure you use a 20 amperage rated cord. Cords rated 

below 20 amperage can overheat. Make sure that the extension cord  is safely secured so it cannot 

be pulled or tripped over. 

 

Note:  Temperature is in Fahrenheit or Celsius.  This heat press should not be set to exceed 

400˚F (200˚C).  Setting the press temperature to above 400˚F (200˚C) may cause a fire hazard.

PLEASE KEEP THE BOX THAT YOUR HEAT PRESS ARRIVED IN, 

 

ALONG WITH ALL ORIGINAL PACKAGING.

Содержание E-HP-JAR-DS-1620

Страница 1: ...Joto Manual Shuttle Press Manual Model No E HP JAR DS 1620 OPERATOR S MANUAL Bringing images to life TM TM This product is SGS Electrical Safety Certified ...

Страница 2: ...ify to do so Instead call or take it to a qualified service person for examination and repair Incorrect assembly or repair could increase the risk of fire electric shock or injury to persons when the equipment is used If heat press being used by or near children please make sure that it is supervised Do not leave equipment unattended while connected Metal parts on the press can become hot Avoid to...

Страница 3: ...ion of this manual requires written consent from Joto Errors and amendments of technical details excepted all rights reserved Joto is not liable for any direct or indirect damages caused by the use of this product Table of Contents Safety 2 Introduction 3 Shuttle Heat Press Overview 4 5 Machine Parts Diagram 6 Setting Up Your Heat Press 7 Operating Instructions 8 Maintenance 9 Heat Pressing Guide ...

Страница 4: ...x 14 87 63cm x 47 93cm x 35 56cm Heat Press platen Size 16 X 20 Maximium Thickness 1 20 30mm Controller GY 06 Digital Controller Voltage 120V 14amp Power 1500W Time Range Maximum Temp 0 999 Seconds 410 F 210 C Packing Size 39 76 x 34 64 x 22 8346 101cm x 88cm x 58cm Gross Weight 209lbs 95kg Note This heat press should not be set to exceed 400 F 200 C Setting the press temperature to above 400 F 20...

Страница 5: ...5 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Heat Press Overview TOP VIEW FRONT VIEW LEFT VIEW RIGHT VIEW ...

Страница 6: ...com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Machine Parts Diagram GY 06 Digital Controller Shuttle Handle Handle Shaft Heat Platen Connection Plate Contol Panel Power Switch Pressure Adjust Knob ...

Страница 7: ...ure Press OK to start Use the up and down arrows to choose to display in F or C F stands for Fahrenheit C stands for Celsius Once selection is made press ok to save Green set temperature value will flash Use the up and down arrows to set press temperature value Press ok to save Setting Press Time Green Set Time Value will flash Use the up and down arrows to change the value Press ok to save the va...

Страница 8: ... counting down Once the timer reaches the last 2 seconds before reaching 0 it will start to beep to warn you Once time reaches zero the press will open Slide the heat platen over to press on the next plate Note Once the press is closed it cannot be opened manually until the timer reaches zero In an emergency you may press the emergency switch to force open the press When pressing the emergency swi...

Страница 9: ...nds Peel Hot to Cold MultiCut Style Temperature 310 330 F Time 15 20 seconds Peel Hot to Cold Transfer Vinyls CL TrimFree Dark REQUIRE A WHITE TONER PRINTER Temperature 310 F 1st Press Time 120 seconds 2nd Press Time 30 seconds Inkjet Light Temperature 350 365 F Time 20 seconds Peel Warm CL TrimFree Light Temperature 330 F Time 30 seconds Peel Warm 5 10 seconds Inkjet Dark Temperature 375 F Time 2...

Страница 10: ...e 120 seconds Peel Immediate Method Substrate face up Image face down iLumipiX Photo Panels Temperature 400 F Time 65 150 seconds Time may varied based on size Scan the QR code on the left for instructions or visit our website Sublimatable Towels Temperature 360 F Time 120 seconds Peel Hot Method Substrate face up Image face down Sublimatable Pillows Temperature 375 F Time 45 seconds Peel Immediat...

Страница 11: ...aten reaches 80 degree C 176 degree F It helps to reduce the temperature of electrical parts and prolong the service life of them Heat platen may pivot slightly back and forth This is due to movement allowance within the clamp assembly and is normal Please add the lubrication oil regularly on the joints to prolong the life of your heat press The frequency will depend on how often you use your mach...

Страница 12: ...12 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Expanded Diagram ...

Страница 13: ...e of Controller Box 1 17 Electromagnet plate 1 55 Left Plate of Controller Box 1 18 GB Fastener Nut LN M8 N 1 56 Power Cord Holder 1 19 Arm 1 57 Power Switch 1 20 Ball Bearing 8 58 Back Plate of Controller Box 1 21 Mat for Electromagnet plate 1 59 Transformer 1 22 GB Fastener Nut SNAB1 M4 N 2 60 Handwheel screw 4 23 Left and Right Handle Plate 1 61 GB Fastener Nut Snc1 M5 N 4 24 Left and Right Han...

Страница 14: ...14 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Circuit Diagram ...

Страница 15: ...r and JOTO will ship the replacement or repaired component freight prepaid by JOTO g This warranty is effective only if the product or component is installed in a location and manner prescribed by JOTO instructions and only if it is maintained in accordance therewith This warranty shall become ineffective if the product or component is altered by anyone other than JOTO employees JOTO neither assum...

Страница 16: ...Bringing images to life TM TM www jotoimagingsupplies com Tel 1 800 565 5686 Fax 1 800 565 5622 Coquitlam BC Brampton ON Blaine WA Las Vegas NV Antioch TN ...

Отзывы: