Safety instructions: 

 

!  The device may only be connected to 115V/60Hz AC voltage power grids.

 

 
!  Only charge batteries that have been approved by the producer with a  

corresponding adapter. Never use other types of batteries or adapter! 

 
!  In industrial institutions it is important to follow the accident protection  

regulations of the industrial employer’s insurance association for electrical systems. 

 
!  Never change the battery charger constructional or open it.  
 
!  Do not use the battery charger in potentially explosive areas. 
 
!  Defective fuses must only be replaced by the equal Types.  

Only instructed or trained personnel are allowed to make changes at the battery charger. 

 
!  The device must only be operated in dry rooms. 
 
!  Ensure that there is sufficient ventilation for the device. During operation the  

ventilation slits at the device must be open. Otherwise the resulting heat  
accumulation would destroy internal electrical components. 

 
!  When the outside temperature changes from cold to warm, wait until room temperature is 

reached, before switching on the device. 

 

!  Defective batteries are hazardous waste. Hazardous waste must be disposed of  

according to applicable regulations. Hand over the defective batteries to your distributor,  
who is responsible for correct disposal. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ULG 36-08

Страница 1: ...Dreyer Strasse 6 8 Tel 0494203 4400 0 E Mail info jotbe com 28844 Weyhe b Bremen Fax 0494203 440010 Internet www jotbe com Battery charger ULG 36 08 Operation manual ...

Страница 2: ...elta Peak Shutdown NiCd NiMH Automatic transition to preservation mode after full charge Detection of defect batteries by electronic charging surveillance Effective charging current from 0 1 3 5 Ampere Protection of wrong polarity by acoustic signal Visualization of error message in case of max charging time exceeding Charging of deep discharged batteries NiCd NiMH Error message in case of battery...

Страница 3: ...e the battery charger in potentially explosive areas Defective fuses must only be replaced by the equal Types Only instructed or trained personnel are allowed to make changes at the battery charger The device must only be operated in dry rooms Ensure that there is sufficient ventilation for the device During operation the ventilation slits at the device must be open Otherwise the resulting heat ac...

Страница 4: ... reason all optical indicator lamps are lighting up After 2 seconds the red indicator lamps switches off and the green indicator lamps make visible that the battery compartments are operation ready Charging After inserting the battery into the battery compartment the green indicator lamp should switching off and the red lamp should switching on The automatic charging process starts in this moment ...

Страница 5: ...attery is charged in combination with the intended adapter Failure to observe may resulting damage to the batteries danger of explosion An additional information Should you charge older batteries NiCd NiMh which have been charged with conventional battery charger before a memory effect that eventually have already occured will be completely eliminated after repeated charging GREEN INDICATOR LAMP I...

Страница 6: ...tone NTC break during charging process 8 x Signal tone TM content not correct 9 x Signal tone For NiCd NiMH more than 20 cells have been detected Troubleshooting Error Cause Solution After the device is switched on not all indicator lamps are lighting up There is an error inside the device Please contact our customer service After inserting the battery a signal tone sounds the adapter used is not ...

Страница 7: ...e 1 2V 24V NiCd and NiMH batteries 3 6V 36V Li Ion and Li Po batteries 2V 24V PB accumulator Charging Current 0 1 3 5 Ampere effective Input 115V AC 50 60Hz 0 48KW Cooling Fan control thermal controlled Protection Class IP20 Dimensions weight ULG36 08 530 x 310 x 320 WxHxD in mm 19 kg We reserve the right to introduce technical changes without prior notice ...

Страница 8: ...Dreyer Strasse 6 8 Tel 049 4203 4400 0 E Mail info jotbe com 28844 Weyhe b Bremen Fax 049 4203 440010 Internet www jotbe com 7 Notes ...