TROUBLE SHOOTING
FAULT
No staples when firing the tool.
Bad clinch
Jammed staple in the nozzle.
ELIMINATION
– Check that the right type of staples is being used
and moves easily.
–
Always use Josef Kihlberg original staples.
– Check if the feeder spring is not defective. If
necessary replace.
– Check if the staple pusher is not defective. If
necessary replace.
– Clean the staple track.
– Air pressure too low. Secure that working pressure
is as recommended, see chapter 6.6.
– Check if the right leg length is used and the sta-
pler is right adjusted, see chapter 6.1.
– Has the tool been used without oil? Provide lubri-
cation, see chapter 5.2.
– Remove the defective staple, see chapter 7.2.
Before all trouble shooting tasks on
the stapler it must first be
disconnected from the air supply.