Jorc FLUIDRAIN-COMBO-QUICKSET Скачать руководство пользователя страница 6

 

 

CLEANING INSTRUCTIONS

 

These instructions are for cleaning the drain. If your drain requires maintenance, i.e. replacement of wearing 
components, please refer to our dedicated maintenance instructions (supplied with the service kit).

              

                                     

                                        

2.1 Close the condensate supply, i.e. close the ball valve.   
2.2 Press the TEST button to empty the unit of any residual condensate and to depressurise the valve. 
2.3 Switch off the electrical supply.  
- Make sure the power is switched OFF before continuing this cleaning operation! 
2.4 Unscrew the valve top nut. 
2.5 Remove the connector, timer and coil assembly from the valve shaft.          
2.6 Unscrew the valve shaft using a 23mm wrench.  
- Do not use the valve shaft as a lever! 
2.7 Clean all the valve parts. 
- Note: if any parts are damaged please replace them using a service kit! 
2.8 Reassemble the inner parts and shaft. Screw the shaft assembly back on to the valve body using a 23mm 
wrench (max. torque 10Nm).          
2.9 Replace the connector, timer and coil assembly on to the valve. Screw on the top nut, make sure the 
gaskets are placed properly to ensure IP65 rating. 
2.10 Switch on the electrical supply. 
2.11 Slowly open the ball valve to restore normal system pressure. 
2.12 Press the test button to check the valve function.                
- Your drain is ready for operation! 

Depressurise the system before installation  
or maintenance is carried out!

 

Содержание FLUIDRAIN-COMBO-QUICKSET

Страница 1: ...1 INSTALLATION MAINTENANCE INSTRUCTIONS 12 2017...

Страница 2: ...afety when operating this product When handling operating or carrying out maintenance on this product personnel must employ safe engineering practices and observe all local health safety requirements...

Страница 3: ...you can mount the timer up right or upside down 1 6 Remove the protection cap from the connector and connect your power cable to the connector as illustrated Close the connector and tighten the botto...

Страница 4: ...4 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11...

Страница 5: ...5 Timer gasket Quick Set Timer Connector gasket Connector Screw Top nut Gasket Coil Valve Shaft Gasket Small spring Large spring Plunger Valve body...

Страница 6: ...coil assembly from the valve shaft 2 6 Unscrew the valve shaft using a 23mm wrench Do not use the valve shaft as a lever 2 7 Clean all the valve parts Note if any parts are damaged please replace them...

Страница 7: ...7 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12...

Страница 8: ...perature 1 55 C 34 131 F Timer range Pressure Capacity 5 10 bar 0 5 20 m min Timer PCB SMD technology Timer cycle indication LED Test feature Yes Valve type 2 2 way direct acting Valve orifice 4 mm Va...

Страница 9: ...9 SERVICE CHART Date Description Name...

Страница 10: ...10 DIMENSIONS mm...

Страница 11: ...eep the first wrench in place Do not use the Valve Shaft as lever Proper installation Screw in a hose barb adapter Use a wrench to lock the valve Use a second wrench to install the hose barb adapter U...