background image

• As default the settings should be set to “Obtain an IP Address automatically”

• Assigning an IP to the PC, ensure that this IP is not the same as the one you used on the modulator or any 

other PC’s you connect to the modulator network. On the example used 192.168.1.200, you can assign 
any IP address of the same network range. If you assign a different IP range (e.g. 192.168.5.xx). PC will not 
respond to the Modulator. 

• Click “OK” to finish your PC settings

IP ADDRESS 192.168.1.200

GATEWAY 192.168.1.1

SUBNET MASK 255.255.255.0

4.2 Login

• You have now assigned an IP address to the PC, 

with the same IP range as the Modulator on the 
network

• Open an internet browser, in the address bar type in 

“192.168.1.168” 
This address will take you to our Modulator GUI

• On the welcome screen, enter the password “1234” 

then click on “Login” or press the "Enter/Return 
Key" to start using the (GUI) graphical user interface

4.2a Log Out

• At the bottom of the side menu, you can click on 

"Log Out" to return back to the Login Screen.

15

DIGITAL MODULATOR - 4 x HDMI INPUTS TO DVB-T MPEG4

Содержание DM/R4HDM4

Страница 1: ...DIGITAL MODULATOR INSTRUCTION MANUAL AUSTRALIA DM R4HDM4 4 HDMI INPUTS TO DVB T MPEG4...

Страница 2: ...ns 9 2 2 Power Precautions 9 2 3 Device s Installation Flow Chart Illustrated in the Following 9 2 4 Environment Requirement 9 2 5 Grounding Requirement 9 CHAPTER 3 OPERATION 10 13 3 1 LCD Menus Using...

Страница 3: ...vice Type 18 4 16 System Parameters System Reset 18 4 17 System Parameters Retrieve Inventory 18 4 18 System Parameters Upgrade Software 18 4 19 System Parameters Set IP 18 4 20 System Parameters Set...

Страница 4: ...ty Note Do not connect the modulator to the power if the power cord is damaged Do not plug the modulator into the mains supply until all cables have been connected Do not cut the cord Servicing WARNIN...

Страница 5: ...st them This can pinch or damage the cords Pay particular attention to cords at plugs outlets and the points where the cords exit the product Make sure the mounting surface or rack is stable and can s...

Страница 6: ...NMS Local Configuration Input Product Code DM R4HDM4 Input Video Audio Input 4 x HDMI Connector Type Type A Encoder Video Resolution Up to 1080p 30 PC Resolution 800 x 600 1024 x 768 1280 x 600 1280...

Страница 7: ...via an RF distribution system To Enable the System Root Menu after the modulator has booted up press the following arrow keys in this sequence LEFT LEFT UP RIGHT DOWN DOWN Press the OK button use the...

Страница 8: ...ideo Source with an HDMI output 5 HDMI 2 Input Port From any Audio Video Source with an HDMI output 6 HDMI 3 Input Port From any Audio Video Source with an HDMI output 7 HDMI 4 Input Port From any Aud...

Страница 9: ...ust be operated maintained and located in a dust free environment Never open the cover of the product After use securely stow away all loose cables and other equipment 2 2 Power Precautions When you c...

Страница 10: ...ffset you can continue to PRESS q to cycle through the main parameters RF Output Enable PRESS OK then PRESS q to Disable if required then PRESS OK Single Tone Disable PRESS OK then PRESS q to Enable i...

Страница 11: ...YES or PRESS q to select n NO if required then PRESS OK Stream Set Service ID PRESS OK Port Number 1 PRESS OK then PRESS q to change to the HDMI Input Port required then PRESS OK Service ID 21010 PRE...

Страница 12: ...hange to the desired reset mode PRESS OK to complete the reset More info on Page 18 4 16 Are you sure y PRESS OK for YES or PRESS q to select n NO if required then PRESS OK System Rtrv Inventory PRESS...

Страница 13: ...s already in the IP range to see the modulator but if it was different then please follow the procedures on the following page To change the IP address of the PC 4 1 NMS IP Setup and Configuration LCD...

Страница 14: ...t icon select Properties with a left click This will now provide you with network protocol connections the PC uses To change the IP address of the PC settings would have to be changed in Network Conne...

Страница 15: ...finish your PC settings IP ADDRESS 192 168 1 200 GATEWAY 192 168 1 1 SUBNET MASK 255 255 255 0 4 2 Login You have now assigned an IP address to the PC with the same IP range as the Modulator on the n...

Страница 16: ...red If changes are made to the Advanced RF Setting please click on Save Settings 4 6 Video Parameters Advanced RF Settings You can set the video parameters for the input source Should you make any cha...

Страница 17: ...Identifier parameters for each of the input sources If any of these parameters are changed please click on Save Settings 4 12 Stream Parameters Set NIT Set the NIT Network Information Table If these...

Страница 18: ...s is being performed Reset to Default Erases all software settings and returns the digital modulator back to factory default If one of these options is selected please click on System Reset 4 17 Syste...

Страница 19: ...on their MATV system Note IP Parameters will have to be loaded in the event of reset to default 19 DIGITAL MODULATOR 4 x HDMI INPUTS TO DVB T MPEG4 All of our products have passed strict testing and i...

Страница 20: ...596 603 7 MHz 599 5 39 MOD 7 603 610 7 MHz 606 5 40 MOD 8 610 617 7 MHz 613 5 41 617 624 7 MHz 620 5 42 624 631 7 MHz 627 5 43 631 638 7 MHz 634 5 44 638 645 7 MHz 641 5 45 645 652 7 MHz 648 5 46 652...

Страница 21: ...T FRONT VIEW OF 19 RACK BACK VIEW OF 19 RACK HDMI outputs from AV Source to the inputs on the Digital Modulators RF outputs from the Digital Modulators for DVB T Distribution RF Combiner 8 Way Splitte...

Страница 22: ...140 3140 4140 5140 6140 7140 8140 PCR PID 170 270 370 470 570 670 770 870 Video PID 170 270 370 470 570 670 770 870 Audio PID 171 271 371 471 571 671 771 871 PID HDMI Input Port 3 PMT PID 1150 2150 31...

Страница 23: ...from the date of purchase Customer Details Name First Name Serial Number Surname Address Name St Ave Drv etc State Suburb Post Code Dealer or Installer Details Name First Name Serial Number Surname A...

Страница 24: ...0 407 www jonsa com au sales jonsa com au Copyright Jonsa Australia Pty Ltd All Rights Reserved WA branch Unit 1 7 Mallaig Way Canning Vale WA 6155 Australia saleswa jonsa com au PO Box 6147 Silverwat...

Отзывы: