JS-3 Jet Sustainer
Flight Manual Supplement
JS03-AFM-00-002
Issue: 00.32JS
Rev. 00.32JS
Rev. Date: 08.02.2019
Page 4
–2
Fuel related inspection
4.3.1
1. Check that the drain in the bottom of the box is clear of obstruction
2. Check for any signs of fuel leaks from the fuel drain
3. Drain a small amount of fuel from the fuel strainer located in the
wheel bay to the left of the main wheel. Check for water or
contaminants.
4. Check fuel level
5. Cycle emergency fuel shutoff switch located in the cockpit (clicking
noise should be audible).
Operational inspection
4.3.2
1. Compare the EGT displayed on the JDU with the ambient OAT.
Compare EGT with ambient air temperature (when OAT is
available)
2. Manually spin compressor blade and verify positive RPM indication
on JDU
3. If airfield is suitable for ground starts, perform a ground start and
ensure the correct functionality of the system.
4. Shutdown engine (if started) and retract engine after the engine
temperatures has stabilized below the retracted temperature.