Owner’s Manual   —   Ultimate 340

Installation, Operation & Service Instructions

Read and Save These Instructions

The Ultimate 340 is one of the most effective and versatile drying devices available. The Ultimate 340 

removes more water and has more grain depression than other refrigerant dehumidifiers, even though it 

only requires 10 amps of electricity.
The term LGR (Low Grain Refrigerant) was created to describe the unique drying capabilities of this 

dehumidifier. These units were known for delivering substantially drier air, as well as for drying areas to 

much lower humidity levels than conventional dehumidifiers. 

 The Ultimate 340 LGR,  

High Capacity Dehumidifier 

•   Improved water removal 

  145 pints per day AHAM (80ºF, 60%)

•   Improved grain depression 

  The driest air from an LGR

•  MERV-11 filtration

•  Multiple ducting options 

 12” intake, 10” lay-flat exhaust

•   Less than 10 amps 

  Removes the most pints of water per kilowatt

•   Stainless steel cabinet

•   Internal pump with 30 feet of hose

•   Five-year warranty on the sealed refrigeration     

  system.

•  12” recessed wheels

•  Solid state controls

Ultimate 340

# OE-ULT340-EA

Specifications subject to change without notice.

TS-620

04/12

The World Leader in Carpet Cleaning, Restoration and Janitorial Supplies  

                  1.800.556-6366

Patent D570,988

Содержание Ultimate 340

Страница 1: ...ntially drier air as well as for drying areas to much lower humidity levels than conventional dehumidifiers The Ultimate 340 LGR High Capacity Dehumidifier Improved water removal 145 pints per day AHA...

Страница 2: ...always be used in the upright position The air inlet on top the side outlet must be at least 1 foot from walls and other obstructions to air flow Read the operation and maintenance instructions caref...

Страница 3: ...before the final purge 2 8 Hour Meter The digital hour meter displays the cumulative and job time the dehumidifier has been turned on to the tenth of an hour The total and job hours measured are stor...

Страница 4: ...claim authorization and technical assistance 4 2 Technical Description The Ultimate 340 uses a refrigeration system similar to an air conditioner s to remove heat and moisture from incoming air and to...

Страница 5: ...d pump phase Unit pumps water automatically but not when PURGE button is pushed 1 Bad connection in PURGE button circuit 2 Defective control board Evaporator coil frosted continuously low dehumidifyin...

Страница 6: ...pump fails and cannot be replaced immediately the Ultimate 340 can be used by draining by gravity 1 Unplug the unit and remove the front cover 2 Push the plastic plug on the right side see Fig 4 out f...

Страница 7: ...L 7 WHT 9 WHT 7 YEL BLU GRY WHT RUN CAPACITOR COMPRESSOR BLOWER MOTOR LEVEL SWITCH RUN CAPACITOR RELAY LOW PRESSURE PUMP FLOAT SAFETY NC NO THERMISTOR PLUG R C S E5 E4 E1 E2 E3 6 0 4 1 WIRE NUT YEL YE...

Страница 8: ...3 EA 1 Front 19 PH 4026304 EA 2 12 Wheel Item Part No Qty Description 20 PH 4026311 EA 1 Axle 21 PH 1284404 EA 2 Cotter Pin 22 PH 4027273 EA 1 Skid Plate 23 PH 4023080 EA 1 Coupling Insert 38 Tube 24...

Страница 9: ...9 www jondon com Toll Free 1 800 556 6366 This page intentionally left blank...

Страница 10: ...tion etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Jon...

Отзывы: