The projector should be installed outside areas where persons m ay walk by or be seated.
Important!
Overhead rigging requires extensive expering CE
,
including
(
but
not
limited
to
)
calculating
working load limits, installation material being used, and periodic safety inspection of all
installation ma-
terial and the projector. If you lack these qualifications, do not attempt the installation yourself, but inste-
ad use a professional structural rigger. Improper installation can result in bodilyinjury and or damage to
property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing system s have
to be used. The projector must never be fixed swinging freely in the room .
Caution Projectors may cause severe injuries when crashing down! If you have doubts
concerning the
safety of a possible installation, do not install the projector!
Before rigging make sure that the installation area can hold a minim um point load of 10 times the
projector s weight.
- 4 -
The projector can be placed directly on the stage floor or rigged in any orientation on atruss without alte-
ring its operation characteristics.
For overhead use,always install a safety-rope that can hold at least 10 times the weight of the fixture.You
must only use safety-ropes with screw on carabines.Pull the safety-rope through the two apertures on the
bottom of the base and over the trussing system etc.
Warning
: it is necessary to make sure that
the installation location is perfectly appropriate,
and the installation location is safe and reliable.
4.3 Power supply connection and cut off
Connect the light source to the main power source with the plug of the power cord, or cut off the power
supply:
Warning:
please verify the power of the power
supply equipment prior to the connection! Earth wire
must be grounded!
4.4 Power Connection
mains with the enclosed power cable and plug.
If you wish to change the power supply settings, see the chapter appendix Connect the fixture to the
L
N
CABLE(EU)
CABLE(US)
Pin
Brown
Black
Live
Yellow/Green
Green
Earth
Light blue
White
Neutral
INTERNATIONAL
4.5 DMX-512 connection/connection between fixtures
Only use stereo shieded cable and 3-pin XLR-plugs and connectors in order to connect.