![jokab safety 2TLJ020030R0000 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/jokab-safety/2tlj020030r0000/2tlj020030r0000_original-instructions-manual_2025483015.webp)
2TLC172083M0201, rev. A
15
www.jokabsafety.com
2011-09-16
NB: 1 holding force test cycle according to GS-ET 19:
a) steady increase of holding force 100 N/s
b) keep max holding force for 5 s.
Safety / Harmonized Standards
Conformity
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2003+A1:2009, EN ISO 12100-2:2003+A1:2009,
EN 954-1:1996/EN ISO 13849-1:2008, EN 1088+A2:2008,
EN 60204-1:2006+A1:2009
VDE 0660 T100, EN 60947-1, VDE 0660 T200, EN 60947-5-1, GS-ET 19
EN ISO 13849-1
Category 1
B
10d
: 2,000,000
Certificates
TÜV Nord, BG, CSA
NB: A single JSNY8 can achieve performance level PL c according to EN ISO 13849 if used correctly with an
ABB/Jokab Safety safety relay, Pluto safety-PLC or Vital safety module. If two JSNY8-switches are used for the
same safety function, a performance level up to PL e can be achieved. Refer to EN ISO 13849 for details on how to
achieve this if necessary.