background image

7

CHAPTER 3

CONSOLE SPECIAL MODE

Category

Name

Default

Range

Internet

Disable/Enable

--

Disable/Enable

MAC ID

Shows the actual

MAC address

--

IP

Shows the actual

IP address

--

AP Mode

OFF

ON/OFF

Export setting to USB

--

Export Wi-Fi setting to USB

Import setting from

USB

--

Import Wi-Fi setting to USB

Signal strength

Disconnected/25%/50%/75%/100%

Reset

--

Reset internet

ERP

--

OFF

OFF~30

3.3 Engineer Mode

Category

Name

Default

Range

Error Codes --

Enable

Enable/Disable

DAPI

Server

Production

Dev/QA/Staging/Production

SSL

ON

ON/OFF

Содержание T3XM

Страница 1: ...JOHNSON Issue Date 2018 4 8 Edition Doc No Revision Date Edition Time Page Johnson Industries Shanghai Co Ltd T3XM Console Service Manual Approval Review Editor Kyle Schweitzer Jerry Zhu...

Страница 2: ...1 Electrical Diagram 9 4 2 Ports Description 10 4 3 Error Code List 11 4 3 1 Speed Errors 11 4 3 2 MCB Errors 11 4 3 3 UCB Error 13 4 3 4 Communication Errors 14 4 4 Console Does Not Light Up 15 SYMPT...

Страница 3: ...1 CHAPTER 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION 1 1 Console Overview T3XM...

Страница 4: ...2 CHAPTER 1 SERIAL NUMBER LOCATION 1 2 Serial Location Model Type Apply List CHAPTE 2 Troubles...

Страница 5: ...ber inputs F UP DOWN INCLINE Adjust incline and make program selections G UP DOWN SPEED Adjust speed and make program selections H UP DOWN TIME Adjust workout time I TOGGLE DISPLAY Cycles between 3 ro...

Страница 6: ...4 CHAPTER 2 CONSOLE INSTRUCTION N BELT DIRECTION Press to change belt direction from forward to reverse O USB PORT Used for software updates only...

Страница 7: ...AL MODE 3 1 Special Mode Browse Mode Name Method Programmer List Special Mode Manage mode 1001 Refer to below picture Engineer mode 2001 Service mode 3001 Test mode 5001 Notes Press to scroll menu Pre...

Страница 8: ...d Standard Metric Software Version UCB LCB Language Wi Fi boot loader Update UCB LCB Language Auto Update Disable Enable Time Check update General Accumulate Distance 0 0 999999 Accumulate Time 0 0 99...

Страница 9: ...l IP address AP Mode OFF ON OFF Export setting to USB Export Wi Fi setting to USB Import setting from USB Import Wi Fi setting to USB Signal strength Disconnected 25 50 75 100 Reset Reset internet ERP...

Страница 10: ...egory Test Procedure Display Press to test display press to back press to scroll menu Keypad Press to test the keypad press to back press to scroll menu CSAFE 1 Press 5 0 0 1 in turn to enter test mod...

Страница 11: ...9 CHAPTER 4 TROUBLESHOOTING CHAPTER 4 TROUBLESHOOTING 4 1 Electrical Diagram T3XM Electrical Diagram...

Страница 12: ...roduction T3XM UCB PORTS DESCRIPTION UCB Front side CN1 USB CN8 Heart Rate CN2 Interface digital CN9 Quick Key Earphone HRT CN3 TV power CN10 TV Keypad CN4 JTAG1 CN11 Main Key CN5 UCB STATUS CN12 C SA...

Страница 13: ...0A0 Fail to rectify speeds C 00A1 No response of motor speed sensor keep time for LCB default C 4 3 2 MCB Errors Error Code Description Class Level 0201 LCB battery low voltage Battery voltage 11 2V A...

Страница 14: ...B2 Safe key action response C 02B3 Machine type error C 02B4 Resistance type error C 02B5 Inverter sensor the normal rated current over 150 can hold 60 seconds C 02B6 Speed up has over current Softwar...

Страница 15: ...tion Press keypad 5 seconds while power ON B 0341 Fan has over current B 0343 UCB has over supply voltage B 0344 Timeout for receiving packet Not recommended for re use make use of 04B0 code B 0345 Co...

Страница 16: ...ts B 0443 MCB read or write wrong B 04A0 LCB LCB has no communication response LCB 3 UCB LCB has no communication command packet from UCB in 3 seconds EUP EUP Wake up mode EUP 400ms 0x7A 2 0x7A Timeou...

Страница 17: ...o the outlet and the machine Check to see if the connection of adapter is well Remove the console and check to see if the console wire has good connected with the console Remove the console mast and c...

Страница 18: ...g out terminals to see if the terminals are connected well 3 Check if Keypad and heart rate metal are connected by multimeter 4 7 Safe Key Issue SYMPTOM The Safe Key has been triggered but the machine...

Страница 19: ...ed It is normally up to 64kB or higher depends on local ISP internet service provider but 0kB means fail to connection Fig 2 3 Browse www google com or any other website Fig 3 If connection fail at st...

Страница 20: ...Wi Fi module into socket carefully Fig 3 4 Fix the Wi Fi Module with 2 pcs of screws Fig 3 5 Install the UCB into consoles 5 1 2 Wi Fi configuration file prepare and uploading 1 Prepare the Wi Fi con...

Страница 21: ...3 seconds and display CSAFE OK Fig 1 3 Press key back to previous menu Fig 2 4 Press speed up key and choice Wi Fi function Fig 3 5 Press enter for auto search Wi Fi Fig 4 6 When you see Wi Fi OK Wi F...