©2017 Johnson Level & Tool

17

10. Product Warranty

Johnson Level & Tool offers a two year limited warranty on each of its products.
You can obtain a copy of the limited warranty for a Johnson Level & Tool 
product by contacting Johnson Level & Tool's Customer Service Department,
as provided below, or by visiting our web site at www.johnsonlevel.com. The
limited warranty for each product contains various limitations and exclusions.

Do not return this product to the store/retailer or place of purchase.  
Non-warranty repairs and course calibration must be done by an authorized
Johnson

®

service center or Johnson Level & Tool's limited warranty, if 

applicable, will be void and there will be NO WARRANTY. Contact one of our
service centers for all non-warranty repairs.  A list of service centers can be
found on our web site at www.johnsonlevel.com or by calling our Customer
Service Department.  Contact our Customer Service Department for Return
Material Authorization (RMA) for warranty repairs (manufacturing defects
only).  Proof of purchase is required.

NOTE: 

The user is responsible for the proper use and care of the product. It is the

responsibility of the user to verify the calibration of the instrument before each use.

For further assistance, or if you experience problems with this product that are not
addressed in this instruction manual, please contact our Customer Service Dept.

In the U.S., contact Johnson Level & Tool’s Customer Service Department at
888-9-LEVELS.

In Canada, contact Johnson Level & Tool’s Customer Service Department at
800-346-6682.

1832i-English_Manuals  4/27/17  2:14 PM  Page 17

Содержание 40-6648

Страница 1: ...eling Cross and Line Laser We suggest you read this instruction manual thoroughly before using the instrument and save this instruction manual for future use This is a Class II laser tool and is manuf...

Страница 2: ...ects up to three laser beams simultaneously to plot both crosslines and a plumb line or either line individually Tilt mode can be used to plot orthogonal reference lines at any angle Magnetically damp...

Страница 3: ...hat may cause someone to unintentionally look into the laser beam Serious eye injury may result Do not operate the tool in explosive environments i e in the presence of gases or flammable liquids Keep...

Страница 4: ...4 2017 Johnson Level Tool 3 Location Content of Warning Labels 1832i English_Manuals 4 27 17 2 14 PM Page 4...

Страница 5: ...ght Locking Compensator Power Switch Battery Cover Release Tab Battery Cover Release Tab Battery Cover Tilt Mode Button Crossline Laser Output Window Plumb Line Laser Output Window 1 4 20 Tripod Threa...

Страница 6: ...er 1 Remove the battery cover which is located at the back of the tool by pressing the battery cover release tabs found on the left and right side of the tool and pulling the cover back 2 Insert 2 AA...

Страница 7: ...within 4 of level for the self leveling feature to function properly If the instrument is beyond its 4 self leveling range the laser will not self level the laser will flash and the status light will...

Страница 8: ...de button a fourth time to power off the unit Tips from the Pros Increasing the Beams Visibility When working in bright conditions such as when working near windows or outside walls the visibility of...

Страница 9: ...e batteries when storing the unit for an extended time more than 3 months to avoid damage to the unit should the batteries deteriorate Avoid getting the unit wet Keep the laser unit dry and clean espe...

Страница 10: ...in a fairly dark room approximately 10 from a doorway 2 Project the plumb beam through the doorway 3 Mark the plumb beam s closet point to the tool on the floor as Point 1 4 Mark a spot 20 away as Po...

Страница 11: ...and power the unit on 3 Face the laser line to the wall and set the center as Point A 4 Make a mark on the wall for Point A 5 Make another mark on the wall 8 from Point A and mark on the wall as Point...

Страница 12: ...two survey staffs OR use two walls both a minimum of 15 from each other 2 Set the instrument on a level tripod as close as possible to staff wall A 3 Power on all laser lines and move the laser until...

Страница 13: ...n the staff wall A Make a mark and label as A2 6 Rotate the instrument by 180 and move the cross dot to project on the staff wall B Make a mark and label as B2 7 Calculate the vertical distance A1 A2...

Страница 14: ...posts Level layout of chair rails wainscoting baseboards etc Installing photographs plumb or level Plumb layout of wallpaper pinstriping plumbing and electrical conduit etc As a level reference for s...

Страница 15: ...a short time Batteries depleted Change the batteries Laser light is dim Batteries depleted Change the batteries Laser light is blinking Laser is out of self leveling range Position laser within 4 of...

Страница 16: ...Self Leveling Range 4 Accuracy 5 32 30 Measuring Range 0 50 Power Supply 2 AA alkaline batteries included Battery Life 10 hours Operating Temperature Range 32 F 104 F Storage Temperature Range 0 F 120...

Страница 17: ...ntact one of our service centers for all non warranty repairs A list of service centers can be found on our web site at www johnsonlevel com or by calling our Customer Service Department Contact our C...

Страница 18: ...ve your information on file for warranty service even if you lose your receipt and lets us contact you if there is ever a product recall We will never sell your information and only send you marketing...

Отзывы: