background image

Thank you for purchasing this Johnson digital level! This level helps 

you accurately determine plumb, level or any angle in between - 

perfect for building ramps, setting drainage pitches and more!

This digital level features:

  

•  Accuracy of 0.10° (at 0°/90°)

•  Accuracy of 0.20° for all other angles

•  Reads in units of in/ft, mm/m, degrees and percent

•  Angled backlit display for easy reading

•  IP54 dust and water resistance

•  Hold and reference modes 

1876 Series Digital Levels Quick Start Guide (1876-2400 • 1876-4800)

www.johnsonlevel.com/manuals

We want to get you up and running as quickly as possible - but this quick start guide is not a replacement for reading and understanding your  

operator’s manual! For complete safety & operating instructions, refer to the operator’s manual included with your tool or scan the QR code.

LCD SCREEN & BUTTON OVERVIEW

LEVEL INDICATORS (2)

SOUND INDICATOR

BATTERY INDICATOR

GETTING STARTED

1.  Insert fresh batteries - see “INSTALLING THE BATTERIES”. 
2.  For best results, calibrate your level prior to each use. See 

“CALIBRATION PROCEDURE” for details.

3.  Power on the digital level by pressing 

.

4.  Enable or disable sound by pressing 

5.  Set your operating units by pressing 

.

6.  Enable the backlight by pressing 

. The backlight will 

automatically turn off after 30 seconds of inactivity. Press any 

button or move the level to re-enable the backlight.

7.  Set the desired auto shutoff timer by pressing and holding 

The LCD will indicate “5” for 5 minutes or “2H” for 2 hours. 

8.  Set a temporary zero reference by pressing 

. See “SETTING A 

ZERO REFERENCE”. To exit reference mode, press 

 again. 

9.  To hold a measurement, press 

. To return to normal operation, 

press 

 again. 

10. During operation, the level indicators will show which direction 

the digital level must be tilted to achieve a reading of zero:

11.  The audio alert will increase in speed as you approach closer to 

zero, and turn into a solid tone when you have achieved zero. 

12.  To power off the level, press 

INSTALLING THE BATTERIES

1.  Always use fresh batteries (2xAAA). 

2.  Use a #1 Philips screwdriver to remove the battery cover. 

3.  Insert the battery according to the polarity indicated on the level 

and in the diagram below.

4.  Replace the cover - do not over-tighten the screw. 

HOLD INDICATOR (2)

UNIT DISPLAY (2)

Powers on/off the level
Enables/disables sound
Sets the temporary zero reference
Changes the displayed unit or auto shutoff timer
Enables/disables the backlight
Freezes the current screen reading
Initiates calibration mode

Move Left Side Up

On Grade

Move Right Side Up

REFERENCE 

INDICATOR (2)

MAIN 

DISPLAY

Отзывы: